Desa S26NTA, S26PTA Cleaning Maintenance, Burner Injector Holder and Pilot Air Inlet Hole

Page 16

Cleaning and

Maintenance

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent clean- ing due to excessive lint from carpeting, bedding material, pet hair, etc.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

Burner Injector Holder and Pilot Air Inlet Hole

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot and primary air inlet holes on injector holder for dust and dirt (see Figure 25).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as- sembly. There is a small pilot air inlet hole about 2" from where the pilot flame comes out of the pilot assembly (see Figure 26). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

 

Injector Holder (May

 

Be Brass or Aluminum

Burner

Depending on Model)

Tube

 

Primary Air Inlet Holes (Shape of Holes May Vary by Model)

Figure 25 - Injector Holder On Outlet

Burner Tube

Ports/Slots

Burner

Tube

Pilot

Assembly

Pilot Air

Inlet Hole

Figure 26 - Pilot Inlet Air Hole

16

www.desatech.com

110361-01G

Image 16
Contents What to do if YOU Smell GAS Table of Contents Safety InformationSafety Information Poisoning may lead to deathProduct Identification Vent-Free Freestanding Pedestal StoveProduct Features Local CodesUnpacking Air For Combustion VentilationAIR for Combustion Ventilation Determining FRESH-AIR Flow for heater LocationConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsClearances to Combustibles Check GAS TypeMinimum Wall and Ceiling Clearances See Figure Connecting to GAS Supply Installation Items NeededChecking GAS Connections Propane/LPNatural Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs Pressure Testing Heater Gas ConnectionsInstalling Blower Accessory GA3750 Installing One-Piece Log set Top ViewInstalling Blower Control Housing Operating Heater For Your Safety Read Before LightingLighting Instructions Operating Heater Inspecting BurnersCleaning Maintenance Burner Injector Holder and Pilot Air Inlet HoleCleaning Maintenance Service HintsTechnical Service SpecificationsTroubleshooting Observed Problem Possible Cause RemedyMaintenance Cleaning Gas leak. See Warning Statement aboveIllustrated Parts Breakdown Models S26PTA and s26nta ShownParts List Illustrated Parts Breakdown Models S26PTA and s26NtaParts List Replacement Parts AccessoriesCleaning KIT CCK Equipment Shutoff Valve GA5010Parts Central Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Pedestal Stove

S26PTA, S26NTA specifications

Desa S26PTA and S26NTA represent the forefront of agricultural technology, offering robust solutions tailored for modern farming needs. These innovative systems cater specifically to agricultural producers looking to enhance efficiency, streamline operations, and improve yields.

One of the main features of Desa S26PTA is its advanced precision agriculture capabilities. Equipped with state-of-the-art GPS technology, it enables farmers to accurately map their fields, monitor crop health, and apply inputs like fertilizers and pesticides with pinpoint accuracy. This not only conserves resources but also minimizes environmental impact, leading to more sustainable farming practices. Additionally, the S26PTA offers real-time data analytics that helps farmers make informed decisions based on current field conditions.

On the other hand, the S26NTA focuses on nutrient management, delivering a comprehensive solution for soil health. Its integrated sensor technology allows for continuous monitoring of soil conditions, assessing moisture levels, pH, and nutrient content. Farmers can access this data through a user-friendly interface, empowering them to optimize their soil management strategies. By fostering healthier soils, the S26NTA contributes to stronger crop development and increased productivity.

Both the S26PTA and S26NTA leverage Internet of Things (IoT) technologies, connecting various sensors and agricultural equipment. This technological integration provides a holistic view of farming operations, ensuring that farmers can monitor and control their systems remotely. The ability to receive alerts and notifications regarding equipment performance or potential issues is invaluable for proactive management.

Moreover, these systems are designed to be user-friendly, with intuitive interfaces that cater to farmers of all tech-savvy levels. Training and support are also integral parts of the package, ensuring that users can maximize the potential of these advanced technologies.

In conclusion, Desa S26PTA and S26NTA exemplify the evolution of agriculture through technology. Their focus on precision farming, nutrient management, and IoT integration offers powerful tools that enhance productivity and sustainability. As the agricultural sector continues to embrace digital transformation, solutions like these will play a crucial role in shaping the future of farming. Farmers adopting these technologies can look forward to optimized operations, improved crop yields, and a positive environmental impact.