Carrier 58MVP instruction manual Fault Code, 0.55¬ RPMRPMhighlow¬

Models: 58MVP

1 48
Download 48 pages 27.19 Kb
Page 30
Image 30

43.

If possible, replace inducer wheel. Otherwise, replace inducer motor assembly.

Ð

Ð

8

44.

Is there any frost build-up on combustion-air inlet?

45

46

Ð

45.

The problem is caused by reversed vent and combustion-air pipes or some other moist air entering

Ð

Ð

14

combustion-air pipe.

 

 

 

 

46.

You have inadequate combustion-air supply. This may be caused by:

 

 

 

- Excessive restriction in combustion-air or vent pipe.

Ð

Ð

14

 

- Internal restriction in coupling box or secondary heat exchangers

 

 

 

47.

Replace pressure switch assembly.

Ð

Ð

70

48.

Is unit a trophy unit?

50

49

Ð

49.

Does fault occur before blower motor turns ON?

47

51

Ð

 

Replace pressure switch assembly with pressure switch assembly used in NON-trophy models or

 

 

 

50.

replace furnace control board. If you replace furnace control board make sure replacement control

Ð

Ð

70

has a date code of 9837 or later. Only replace the pressure switch assembly or the furnace control

 

 

 

 

 

board NOT both.

 

 

 

51.

Replace furnace control board.

Ð

Ð

70

52.

Turn power off and disconnect jumper wire across R and W/W1 thermostat terminals.

Ð

Ð

53

53.

Turn power on and wait several sec before proceeding to next step.

Ð

Ð

54

54.

Disconnect collector box tube to pressure switch assembly.

Ð

Ð

55

55.

Jumper R and W/W1 thermostat terminals on furnace control board.

Ð

Ð

56

56.

Does Fault Code 42 occur within 11 sec after a call for heat?

57

58

Ð

57.

Reconnect collector box tube to pressure switch assembly.

Ð

Ð

10

58.

Reconnect collector box tube to pressure switch assembly.

Ð

Ð

36

59.

Go to page number indicated in Index for CLEANUP AND STARTUP INSTRUCTIONS. If problem

Ð

Ð

INDEX

persists on an intermittent basis, contact your distributor.

 

 

 

 

60.

Turn power off and disconnect jumper wire across R and W/W1 thermostat terminals.

Ð

Ð

61

61.

Turn power on and wait several sec, then jumper R, W/W1, and W2 thermostat terminals on fur-

Ð

Ð

62

nace control board.

 

 

 

 

 

Does fault occur a few sec after high-pressure switch HPS makes?

 

 

 

62.

NOTE: Check for 24v between the N.O. (Normally Open) contact on high-pressure switch

63

67

Ð

 

HPS and Com on furnace control board to know when high-pressure switch HPS makes.

 

 

 

63.

Turn power off and disconnect jumper wire across R, W/W1, and W2 thermostat terminals.

Ð

Ð

64

64.

Connect 1 side of a slope manometer with a tee to collector box pressure tap. Connect other side

Ð

Ð

65

with a tee to gas valve air pressure fitting. Refer to pressure check diagram in Appendix C.

 

 

 

 

65.

Turn power on and wait several sec, then jumper R, W/W1, and W2 thermostat terminals on fur-

Ð

Ð

66

nace control board.

 

 

 

 

 

 

 

 

 

 

Do you have more than 1.9 in. wc pressure drop across heat exchangers when high-pressure

 

 

 

66.

switch HPS makes?

47

44

Ð

NOTE: Check for 24v between the N.O. (Normally Open) contact on high-pressure switch

 

 

 

 

 

HPS and Com on furnace control board to know when high-pressure switch HPS makes.

 

 

 

 

 

 

 

 

67.

Does fault occur a few sec after main burners ignite?

63

68

Ð

 

 

 

 

 

68.

Observe operation of furnace in high heat for next 8 minutes or until fault occurs.

Ð

Ð

69

 

 

 

 

 

69.

Does the fault occur?

22

59

Ð

 

 

 

 

 

70.

If problem still persists check for internal restriction in coupling box or secondary heat exchangers.

Ð

Ð

14

 

 

 

 

 

Fault Code 43

PRESSURE SWITCH CALIBRATION FAULTÐIndicates low-pressure switch LPS and high-pressure switch HPS "make" points during high-heat purge are not within calibration range. This is determined by reading inducer motor RPM when low-pressure switch LPS and high-pressure switch HPS make. Then the following comparison is made:

0.55¬ RPMRPM (high)(low) ¬ 0.90

If this relationship is not within range specified, furnace control board starts flashing fault colde 43, shuts unit down (inducer runs for 15 sec), waits 2 minutes, stops flashing fault code, and restarts heating cycle.

It can also indicate that the high-pressure switch HPS made before the low-pressure switch LPS during either low-heat or high-heat purge.

STEP

ACTION

YES

NO

GO TO

1.

Turn power off, remove blower access panel, and disconnect all thermostat leads from furnace con-

Ð

Ð

2

trol board.

 

 

 

 

2.

Turn power on and depress door switch. Use a piece of tape to hold switch closed.

Ð

Ð

3

3.

Jumper R, W/W1, and W2 thermostat terminals on furnace control board.

Ð

Ð

4

30

Page 30
Image 30
Carrier 58MVP instruction manual Fault Code, 0.55¬ RPMRPMhighlow¬