Drolet 75281 owner manual Floor Protector

Page 13

FLOOR PROTECTOR

Your wood stove should be placed on a non-combustible surface. The floor protector should be under the stove, eighteen inches beyond the front and eight inches beyond each side of the fuel loading and ash removal opening. If there is a horizontal section of chimney connector, the floor protector should go under it and two inches beyond each side.

The floor protector should exceed the stove as follows:

FRONT SIDES BACK

18’’ 8’’ 8’’ (460 mm) (200 mm) (200 mm)

12

Image 13
Contents Read and Keep this Manual for Reference OWNER`S Manual Drolet EPA WoodstovesTable of Contents Introduction Overall Technical SpecificationsTips on Wood Heating Pedestal and Decorative Sidewall Installation AssemblyHT-1600 Refractory Bricks Assembly Bricks and Insulation Installation HT-1600HT-2000 Refractory Bricks Assembly Brick and Insulation Installation HT-2000Air Tubes Installation AIR Tubes Installation HT-2000Door Adjustment Door AdjustmentBenefits of Installing a Blower Positioning the Stove InstallationFloor Protector Canada ClearancesType of Protection Reduced ClearancesChimney Chimney Connector Stove Pipe Factory Built Chimney Typical InstallationsClay liner Factory Built Thimble Brick Thimble Average Energy Yield Of One Air Dried Cord Of Cut Wood Woodstove UtilizationFirst Fires Testing Your WoodIgnition Heating Creosote Formation and Need for Removal ReloadingASH Disposal Glass MaintenanceGasketing PaintDrolet Limited Lifetime Warranty