Drolet 75281 owner manual Technical Specifications, Overall

Page 4

TECHNICAL SPECIFICATIONS

 

 

HT-1600

HT-2000

 

 

 

 

Combustion Type:

 

Wood

Wood

Recommended Surface

 

900 à 1 600 ft2

1 000 à 2 000 ft2

 

 

(84 à 149 m2)

(93 à 186 m2)

Heating Capacity :

E.P.A :

40 000 BTU/h

60 200 BTU/h

(11,7 kW)

(17,6 kW)

 

 

 

Real :

70 000 BTU/h

95 000 BTU/h

 

(20,5 kW)

(27,8 kW)

 

 

Efficiency :

 

71,3%

72,2%

Average Emission:

 

3,3 g/h

3,8 g/h

Colour :

 

Metallic Black

Metallic Black

Flue Pipe Diameter :

 

6’’ (152 mm)

6’’ (152 mm)

Chimney type :

 

2 100°F (650 °C)

2 100°F (650 °C)

Minimum Chimney Height :

12’ (3,66 m)

12’ (3,66 m)

Maximum Log Length :

 

18’’ (457 mm)

19’’ (483 mm)

Dimensions

 

W x D x H

W x D x H

Overall:

 

On Pedestal Model : 25 1/8 x 26 ½ x 32 5/8‘’

28 3/8 x 29 ½ x 34 3/8

 

 

(638 x 673 x 828mm)

(721 x 749 x 873mm)

Combustion Chamber :

 

18 ¼ x 15 ¼’’

22 ½ x 18’’

Width x Depth :

 

 

(464 x 387 mm)

(572 x 457 mm)

 

Volume :

2,5 pi3 (0,07 m3)

3,4 pi3 (0,09 m3)

Door Opening :

 

17 ¾ x 9 1/8'’

17 3/4 x 9 1/8

Width x Height :

(425 x 222 mm)

(450 x 234 mm)

 

 

Pyroceram Glass Door :

 

16 ¼ x 9 ½’’

16 1/4 x 9 1/2

Width x Height :

(432 x 267 mm)

(413 x 241 mm)

 

 

Mass:

 

420 lbs (190 Kg)

560 lbs (254 Kg)

OPTIONS

Blower 75 CFM (2,83 m3/min) with variable speed control Thermodisc 100-120oF (37-490C).

YesYes

YesYes

3

Image 4
Contents OWNER`S Manual Drolet EPA Woodstoves Read and Keep this Manual for ReferenceTable of Contents Introduction Technical Specifications OverallTips on Wood Heating Assembly Pedestal and Decorative Sidewall InstallationBricks and Insulation Installation HT-1600 HT-1600 Refractory Bricks AssemblyBrick and Insulation Installation HT-2000 HT-2000 Refractory Bricks AssemblyAIR Tubes Installation HT-2000 Air Tubes InstallationDoor Adjustment Door AdjustmentBenefits of Installing a Blower Installation Positioning the StoveFloor Protector Clearances CanadaReduced Clearances Type of ProtectionChimney Chimney Connector Stove Pipe Typical Installations Factory Built ChimneyClay liner Factory Built Thimble Brick Thimble Woodstove Utilization Average Energy Yield Of One Air Dried Cord Of Cut WoodFirst Fires Testing Your WoodIgnition Heating Reloading Creosote Formation and Need for RemovalASH Disposal Maintenance GlassGasketing PaintDrolet Limited Lifetime Warranty