England's Stove Works 55-TRP22E operation manual Adjusting your Hopper Lid Latches

Page 18

Adjusting your Hopper Lid Latches

The seals around the top of the pellet hopper are important to safe and efficient operation of the unit. The latches installed on these units are designed to pull the hopper lid tight against this seal. Over the course of operation as these seals “wear in” and compress, the tension of the latches should be tested periodically, and adjusted if necessary.

To adjust the lid latches, the following tools will be needed; two ½ inch wrenches, or a ½ inch wrench and a ½ inch socket.

In order to adjust the latch, first open the hopper lid and then lock the latch in its closed position. Then take the ½ inch wrench and loosen the nut closest to the latch. This nut is then adjusted closer to the lid itself to tighten the latch. After adjusting this nut to the desired location, hold this nut in place with the ½ inch wrench, the tighten down the holding nut on the end of the latch shaft with the ½ inch socket or second wrench to hold the latching assembly in place

After tightening the latches, test the latches for proper tension by locking the lid down and lifting each front corner of the lid. The lid should be firmly held down by the latches. Repeat the same procedure if the latch is still not tight enough.

Illustration 3 – Hopper Lid Latches

Important: Hopper Lid Latches must be checked periodically and kept tight so the top is sealed to prevent back-burn.

18

Image 18
Contents Model Numbers Be maintainedLetter from our Technical Support department Important Information Unit Preparation Questions, parts/accessory orders and more Flue System Pellet Vent PipeThrough the Wall Existing Flue System Mobile Home InstallationThrough the Ceiling Outside Air Outside Combustion Air IntakeFloor and Wall Protection Floor ProtectionWall Protection Operating Instructions Horizontal Feed SystemManually Starting Your Unit SHUT-DOWN Procedure CodesDaily Operation ASH Removal and Disposal Semi-Weekly Ash RemovalAnnual Cleaning Monthly Ash RemovalAuger Motors MaintenanceRear Panel Removal Auger Bearings and Auger ShaftsCombustion Blower Vacuum SwitchConvection Blower GasketsControl Board Recommended Heat RangesIllustration 2b Control Board Diagram Wiring Adjusting your Hopper Lid Latches Thermostats AC-103, AC-103BN Lip TrimAC-106-P SH-106-P, AC-106-PBN Window Trim Replacement PARTS, Accessories and Options Technical Support DepartmentBox Parts Orders only Monroe, VA Questions 800-245-6489 Fax Pellet Stove Exploded View Diagram TROUBLE-SHOOTING Guide Problem Cause SolutionWarranty is not Transferable Page Warranty Registration for England’s Stove Works
Related manuals
Manual 24 pages 43.38 Kb