INSTALLATION

Approved Venting Method: Full Chimney Relining

Use a chimney liner system specifically designed for pellet stove use; follow the guidelines in the previous section regarding appropriate liner diameter.

Use the tee supplied by the liner manufacturer to connect the exhaust outlet of the stove to the chimney lining system.

Seal the throat of the fireplace with a sheet metal block-off plate screwed to the walls of the fireplace.

Seal the top of the chimney opening using the Top Plate provided by the liner manufacturer (or, for abnormal installations, fabricate the top plate from sheet metal).

Use High Temp RTV silicone to seal the top plate and prevent leaks.

If the liner system is not a “Twist-Lock” design, all joints should be secured with three sheet metal screws.

Seal all joints in the liner using High Temp

RTV silicone.

Secure the outside air pipe to the stove using a hose clamp or other mechanical fastener. The outside air pipe may be run to the top of the chimney system and terminated (as shown above), or may be run down through the ash dump, in the case of a masonry fireplace.

Please Note:

Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual installation. Please follow all venting system requirements and maintain the required clearances to combustibles.

Page 12

Image 12 Contents
Safety Notice Evolution Pellet Insert & Insert KITRetain for your files Table of Contents Introduction Specifications Heating Specifications Installation Tools Required Installation Unit Clearances to Combustibles Installation Installation Please Note Outside AIR HOOK-UP Floor Protection Daily Operation Page Control Board Settings Error Codes Power Failure OFFThermostat Operation Thermostat Operation Daily Maintenance Daily Maintenance Daily Maintenance Biweekly Maintenance Biweekly Maintenance Monthly Maintenance Monthly Maintenance Monthly Maintenance Yearly Maintenance Yearly Maintenance Page Yearly Maintenance Yearly Maintenance Trouble­Shooting Guide Unit Shuts Down in 15‐20 Replacing Components Replacing Components Replacing Components Replacing Components Recommended Heat Ranges Wiring Diagram Optional Accessories Standard AccessoriesIllustrated Parts Diagram Replacement Parts List Limited Five 5 Year Warranty Warranty is not transferable Warranty Registration for England’s Stove Works Important Notice