England's Stove Works 25-EPI operation manual Outside AIR HOOK-UP

Page 13

OUTSIDE AIR HOOK-UP

The use of outside combustion air is mandatory on the 25-EP Insert.

The outside air connection pipe protrudes from the lower rear center of the stove; use the included outside air kit to attach your stove to outside combustion air. Instructions and all the parts needed to make the outside air connection to your pellet stove are included with the outside air kit.

Outside air can be drawn from an outside air system which terminates ath the top of the chimney opening or down through the ash dump (if your fireplace is so equipped.) The best choice for outside air connection is the one which uses the shortest distance or outside air pipe.

If it is not feasible to use the included outside air hookup kit in your stove installation, other materials may be used provided the following rules are followed:

oThe pipe used for outside air hookup must be metal, with a minimum thickness of .0209 in. (25 gauge mild steel) or greater and an inside

diameter of approximately 2.0in.

oAll pipe joints and connections should be sealed with pipe clamps or other mechanical means, to insure a leak free outside air connection.

oLong runs of pipe and excessive elbows for outside air should be

avoided. Due to frictional resistance in pipe, any excessive outside air piping can result in poor stove performance.

oA screen or other protection device must be fitted over the outside air

termination point to prevent rain, debris and nuisance animals from entering the piping system.

oIncrease the outside air pipe size to 3.0 in. diameter pipe if the outside air connection is more than 6ft. in length, more than two (2) elbows are used or if the stove is installed in a basement.

The outside air connection system should be inspected at least annually to be certain it is free from blockage.

Caution

NEVER draw outside combustion air from:

Wall, floor or ceiling cavity

Enclosed space such as an attic, garage or crawl space.

Page 13

Image 13 Contents
Evolution Pellet Insert & Insert KIT Safety NoticeRetain for your files Table of Contents Introduction Specifications Heating Specifications Tools Required InstallationInstallation Unit Clearances to Combustibles Installation Installation Please Note Outside AIR HOOK-UP Floor Protection Daily Operation Page Control Board Settings Error Codes OFF Power FailureThermostat Operation Thermostat Operation Daily Maintenance Daily Maintenance Daily Maintenance Biweekly Maintenance Biweekly Maintenance Monthly Maintenance Monthly Maintenance Monthly Maintenance Yearly Maintenance Yearly Maintenance Page Yearly Maintenance Yearly Maintenance Trouble­Shooting Guide Unit Shuts Down in 15‐20 Replacing Components Replacing Components Replacing Components Replacing Components Recommended Heat Ranges Wiring Diagram Standard Accessories Optional AccessoriesIllustrated Parts Diagram Replacement Parts List Limited Five 5 Year Warranty Warranty is not transferable Warranty Registration for England’s Stove Works Important Notice