Installation

OUTSIDE FRESH-AIR CONNECTION:

Outside fresh air is mandatory when installing this unit in airtight homes and mobile homes.

A Fresh-air intake is strongly recommended for all installations. Failure to install intake air may result in improper combustion as well as the unit smoking during power failures.

When connecting to an outside fresh air source, do not use plastic or combustible pipe. A 15⁄8” minimum (42 mm) ID (inside diameter) steel, aluminum or copper pipe should be used. It is recommended, when you are installing a fresh air system, to keep the number of bends in the pipe to a minimum.

�������

����

� ��

��� ���

��������

�����

EXHAUST AND FRESH AIR INTAKE LOCATIONS:

Figure 10: Outside Air Connection.

EXHAUST

 

 

Base of unit to center of flue

10 15/16

(278 mm)

Center of unit to center of flue

1 3⁄8”

(35 mm)

FRESH AIR INTAKE.

 

 

Base of unit to center of intake

8 15/16

(227 mm)

Center of unit to center of intake

41⁄8”

(105 mm)

8

15/16"

10

15/16"

(278 mm)

(227 mm)

 

 

 

4 1/8"

1 3/8"

 

 

(105 mm)

(35 mm)

 

 

Figure 11: EF5 Inlet and Outlet Location.

 

16

Image 16
Contents Evolution Table of Contents I. Pellet Standards IntroductionStore pellets at least 36 1 m away from the pellet stove USE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Reasons WHY the Unit Overheated Operating InstructionsThermostat / Switch Mode Initial START-UP See aboveRoutine Cleaning and Maintenance Tools Required to Clean UnitBurner POT and Liner 2-3 days Heat Exchanger Tubes 2-3 daysDoor Glass Cleaning 2-3 days ASH PAN weeklyFresh AIR Intake biannually Exhaust Passages biannuallyPost Season CLEAN-UP Cleaning Plated SurfacesDoor Glass Replacement Brick PanelInstallation Screws to take out to remove stove from palletDimensions of EF5 Minimum Alcove depth Inches Installing Hearth Pad Pedestal onto EF5 Crawlspace, narrow Walkway Closely Exhaust Fresh Air Intake Page Venting horizontally with rise Inside Vertical Installation Outside Vertical Installation Through vent hole Exterior Blower KitThrough Wall Installation with Exterior Blower Kit EF5 If you wish to adjust the slider damper externally not REQUIRED, please follow the instructions belowSlider Damper Located Behind Left Side panel. To open Special NotesTroubleshooting Stove will not operate when hotDo not What to do ifExhaust motor will not function normally 200 F 93 C high limit temperature sensor has trippedLight # 2 on Heat output bar flashing Control settings Heat Level has no effect on the fire Convection blower will not function normallyIgnitor- the pellets will not light Stove keeps going outWiring Diagram 5V DCParts List Reference Number Description Part Number50-1085 Parts Diagram Components SteelDiagramParts To the Dealer WarrantyTo the Distributor Installation Data Sheet Name of Owner Address

C-10608 specifications

Enviro C-10608 is an innovative solution designed to address the increasing environmental concerns related to chemical waste management and pollution control. Leveraging state-of-the-art technologies and advanced material science, Enviro C-10608 provides a comprehensive approach to minimizing the ecological footprint of industrial operations.

One of the main features of Enviro C-10608 is its exceptional versatility. It can be utilized across various sectors, including manufacturing, oil and gas, and agriculture. This adaptability makes it a valuable asset for organizations looking to comply with stringent environmental regulations while improving their sustainability practices. By effectively treating and managing waste materials, Enviro C-10608 promotes circular economy principles and helps companies reduce their reliance on raw materials.

Moreover, Enviro C-10608 employs cutting-edge filtration technologies that enhance its performance significantly. Its advanced filtration system is designed to capture a wide range of contaminants, including heavy metals, toxins, and organic compounds, ensuring that discharged effluents meet or exceed environmental standards. This not only protects local ecosystems but also safeguards public health, making it an essential tool in modern waste management.

Another notable characteristic of Enviro C-10608 is its low energy consumption. The product is engineered to operate efficiently, reducing the overall carbon footprint associated with waste treatment processes. This energy efficiency is further complemented by its use of renewable energy sources, further enhancing its appeal to environmentally conscious organizations.

Additionally, Enviro C-10608 features real-time monitoring and reporting capabilities. This technological integration allows for the continuous assessment of treatment efficiency and compliance levels, ensuring that users can make informed decisions based on accurate data. The user-friendly interface simplifies the monitoring process, enabling companies to adapt their operations swiftly in response to changing environmental regulations.

Finally, Enviro C-10608 stands out for its commitment to safety and user-friendliness. Designed with straightforward installation and operation procedures, it minimizes downtime and training requirements for staff. The product’s materials are non-toxic and sustainable, promoting a healthier work environment.

In conclusion, Enviro C-10608 embodies a forward-thinking approach to waste management. With its versatile applications, advanced filtration technologies, energy efficiency, real-time monitoring, and commitment to safety, it is poised to become a cornerstone in the sustainable practices of industries worldwide.