Enviro C-10608 owner manual Outside Vertical Installation

Page 21

Installation

Rain cap

 

Flashing

 

 

36"

 

(91.5 cm)

 

3" (7.5 cm)

3"

Clearance

 

(7.5cm)

Support

 

 

bracket

 

Tee with

 

cleanout

 

Type "L"

 

vent

 

Fresh air

 

intake

Figure 18: Outside Vertical Installation.

HEARTH MOUNT INSTALLATION:

Rain Cap

Seal Plate

Existing Masonary

Flue

Vent Pipe (single

wall stainless flex

pipe or PL vent)

Flexible Vent Connector

(Use this 5 ft section of

pipe to vent past

fireplace damper or

smoke shelf)

Fireplace Damper Location

Clean Out Tee Existing Fireplace

EF 5

Refer to Figures 19.

1.Lock fireplace damper in the open position.

2.Install a positive flue connector at the fireplace dampers.

3.Connect a tee or a 90° elbow to the exhaust pipe.

4.Install flexible stainless steel liner or listed pellet vent to the top of the chimney.

Figure 19: Hearth mount installation.

21

Image 21 Contents
Evolution Table of Contents Introduction I. Pellet StandardsStore pellets at least 36 1 m away from the pellet stove USE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Operating Instructions Reasons WHY the Unit OverheatedInitial START-UP See above Thermostat / Switch ModeTools Required to Clean Unit Routine Cleaning and MaintenanceBurner POT and Liner 2-3 days Heat Exchanger Tubes 2-3 daysASH PAN weekly Door Glass Cleaning 2-3 daysFresh AIR Intake biannually Exhaust Passages biannuallyCleaning Plated Surfaces Post Season CLEAN-UPDoor Glass Replacement Brick PanelScrews to take out to remove stove from pallet InstallationDimensions of EF5 Minimum Alcove depth Inches Installing Hearth Pad Pedestal onto EF5 Crawlspace, narrow Walkway Closely Exhaust Fresh Air Intake Page Venting horizontally with rise Inside Vertical Installation Outside Vertical Installation Exterior Blower Kit Through vent holeThrough Wall Installation with Exterior Blower Kit EF5 REQUIRED, please follow the instructions below If you wish to adjust the slider damper externally notSpecial Notes Slider Damper Located Behind Left Side panel. To openStove will not operate when hot TroubleshootingDo not What to do if200 F 93 C high limit temperature sensor has tripped Exhaust motor will not function normallyLight # 2 on Heat output bar flashing Convection blower will not function normally Control settings Heat Level has no effect on the fireIgnitor- the pellets will not light Stove keeps going out5V DC Wiring DiagramReference Number Description Part Number Parts List50-1085 Parts Diagram Components SteelDiagramParts Warranty To the DealerTo the Distributor Name of Owner Address Installation Data Sheet