Enviro C-10608 Exhaust motor will not function normally, Light # 2 on Heat output bar flashing

Page 28

Troubleshooting

üPoor Quality Fuel – Insufficient energy in the fuel to produce enough heat to keep the stove burning or operational.

üExhaust Temperature Sensor failure. – Bypass sensor located on Exhaust Blower if stove now operates properly, the unit may require cleaning or a new sensor. Contact your local dealer for service.

üCheck the fuses on the circuit board (see “Troubleshooting - Fuses”).

3. The exhaust motor will not function normally.

üOpen the left side access panel; check all connections against the wiring diagram. üSee “2. The stove will not operate when hot.” section.

4. Light # 2 on Heat output bar flashing

(The Vacuum Switch contacts have opened for more than 15 sec.)

üPinch, break or blockage in Vacuum Hose - Check hose for pinch points or damage, replace or re-route as required. Blow out Vacuum Hose

üBlocked Hose Barb on Exhaust Channel - Use a paper clip to clean out Hose Barb or remove the Vacuum Hose from the Vacuum Switch and blow into the hose to remove blockage.

üBlocked exhaust / venting system - Have stove and venting cleaned and inspected.

üSevere negative pressure in area where unit is installed - Check the operation by opening a window, does this solve the problem? If it does, install fresh air intake to unit or room. Venting system may require vertical section to move termination into a low pressure zone.

üVacuum Switch failure - Bypass the vacuum switch, if this corrects the problem check for above problems before replacing the Vacuum Switch.

üDamage to gray wires between Circuit Board and Vacuum Switch - Inspect wires and connectors

üCombustion Blower failure - The Combustion Blower is not turning fast enough to generate the proper vacuum in the Exhaust Channel. Visual Check; is the blower motor turning? Check the Exhaust Blower voltage across the blower wires (>=114 V on #5 setting and >= 82 V on #1 setting). – Replace the Circuit Board if the Voltage reading is less than 82 V. with a line voltage >114 V AC.

üCheck Vacuum levels in the exhaust channel by bypassing the vacuum switch, then remove the Vacuum hose from Vacuum Switch. Check exhaust vacuum readings by placing the open end of the Vacuum Hose on a Magnahelic Gauge. (readings must be above .10” W.C. on low fire).

If the motor fails to reach a 0.10” W.C. readings, then replace the Combustion Blower

To reset Circuit Board after a trouble code - push the ON/OFF button 5. Auger light flashes but auger motor does not turn at all.

üIf the Auger gear box does not turn but the motor’s armature does try to spin then the auger is jammed.

Try to break apart jam by poking at the jam through the drop tube. If this fails then empty the hopper and remove the Auger Cover **Remember to re-seal the cover after installation**

üCheck the fuses on the circuit board (see “Troubleshooting - Fuses”).

6. The 200 °F ( 93 °C) high limit temperature sensor has tripped.

üReset sensor and determine cause – was it Convection Blower failure or 160 °F ( 71 °C) Temperature Sensor failure? Bypass the 160 °F ( 71 °C) sensor, does the Convection blower come on high if not replace the blower? If yes, replace sensor (located on the left side of the firewall).

üCheck the fuses on the circuit board (see “Troubleshooting - Fuses”).

28

Image 28
Contents Evolution Table of Contents I. Pellet Standards IntroductionStore pellets at least 36 1 m away from the pellet stove USE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Reasons WHY the Unit Overheated Operating InstructionsThermostat / Switch Mode Initial START-UP See aboveRoutine Cleaning and Maintenance Tools Required to Clean UnitBurner POT and Liner 2-3 days Heat Exchanger Tubes 2-3 daysDoor Glass Cleaning 2-3 days ASH PAN weeklyFresh AIR Intake biannually Exhaust Passages biannuallyPost Season CLEAN-UP Cleaning Plated SurfacesDoor Glass Replacement Brick PanelInstallation Screws to take out to remove stove from palletDimensions of EF5 Minimum Alcove depth Inches Installing Hearth Pad Pedestal onto EF5 Crawlspace, narrow Walkway Closely Exhaust Fresh Air Intake Page Venting horizontally with rise Inside Vertical Installation Outside Vertical Installation Through vent hole Exterior Blower KitThrough Wall Installation with Exterior Blower Kit EF5 If you wish to adjust the slider damper externally not REQUIRED, please follow the instructions belowSlider Damper Located Behind Left Side panel. To open Special NotesTroubleshooting Stove will not operate when hotDo not What to do ifExhaust motor will not function normally 200 F 93 C high limit temperature sensor has trippedLight # 2 on Heat output bar flashing Control settings Heat Level has no effect on the fire Convection blower will not function normallyIgnitor- the pellets will not light Stove keeps going outWiring Diagram 5V DCParts List Reference Number Description Part Number50-1085 Parts Diagram Components SteelDiagramParts To the Dealer WarrantyTo the Distributor Installation Data Sheet Name of Owner Address

C-10608 specifications

Enviro C-10608 is an innovative solution designed to address the increasing environmental concerns related to chemical waste management and pollution control. Leveraging state-of-the-art technologies and advanced material science, Enviro C-10608 provides a comprehensive approach to minimizing the ecological footprint of industrial operations.

One of the main features of Enviro C-10608 is its exceptional versatility. It can be utilized across various sectors, including manufacturing, oil and gas, and agriculture. This adaptability makes it a valuable asset for organizations looking to comply with stringent environmental regulations while improving their sustainability practices. By effectively treating and managing waste materials, Enviro C-10608 promotes circular economy principles and helps companies reduce their reliance on raw materials.

Moreover, Enviro C-10608 employs cutting-edge filtration technologies that enhance its performance significantly. Its advanced filtration system is designed to capture a wide range of contaminants, including heavy metals, toxins, and organic compounds, ensuring that discharged effluents meet or exceed environmental standards. This not only protects local ecosystems but also safeguards public health, making it an essential tool in modern waste management.

Another notable characteristic of Enviro C-10608 is its low energy consumption. The product is engineered to operate efficiently, reducing the overall carbon footprint associated with waste treatment processes. This energy efficiency is further complemented by its use of renewable energy sources, further enhancing its appeal to environmentally conscious organizations.

Additionally, Enviro C-10608 features real-time monitoring and reporting capabilities. This technological integration allows for the continuous assessment of treatment efficiency and compliance levels, ensuring that users can make informed decisions based on accurate data. The user-friendly interface simplifies the monitoring process, enabling companies to adapt their operations swiftly in response to changing environmental regulations.

Finally, Enviro C-10608 stands out for its commitment to safety and user-friendliness. Designed with straightforward installation and operation procedures, it minimizes downtime and training requirements for staff. The product’s materials are non-toxic and sustainable, promoting a healthier work environment.

In conclusion, Enviro C-10608 embodies a forward-thinking approach to waste management. With its versatile applications, advanced filtration technologies, energy efficiency, real-time monitoring, and commitment to safety, it is poised to become a cornerstone in the sustainable practices of industries worldwide.