Enviro C-10608 owner manual Operating Instructions, Reasons WHY the Unit Overheated

Page 6

Operating Instructions

CONTROL BOARD FUNCTIONS:

1.AUGER TRIM: Used to change feed rates on LOW ONLY for poorer quality fuels. Push the Auger Trim button until the number 1 and 5 lights appear on the Heat Level Indicator. This will increase the feed rate to 4 seconds ON time Auger pulse. This is done only on LOW to allow the burning of poor quality fuels. Push the button until the number 1 and 4 lights appear, this will reduce the Auger On time to 2 second. This setting is for high-grade fuel only. Push the button until just the number 1 light is on, this is for a three (3) second on time (standard setting).

2.CONVECTION BLOWER CONTROL: Used to turn the convection blower ON/OFF. If the Blower is left off, and the sensor located on the air jacket reaches 160 °F (71 °C), the Convection blower will automatically come on HI speed to cool the unit. Leave the convection blower ON for peak efficiency

3.AUGER PULSE LIGHT: This light will flash in conjunction with the auger.

 

AUGER TRIM

 

 

 

FAN

 

 

 

MANUAL FEED

 

 

ON/OFF

 

HEAT LEVEL

Figure 1: Circuit Board Control Panel Decal

4.MANUAL AUGER FEED: If the unit runs out of fuel, this button can be used to “prime the auger system”. This button will turn off after 60 seconds and then must be released and pressed again.

5.SYSTEM LIGHT: Responsible for signaling the state of the control board. When the light is flashing during start-up, the stove is in an automatic start mode. When the light is solid, the Heat Level Setting can be altered.

6.ON/OFF BUTTON: Used to turn the unit ON and OFF.

7.HEAT OUTPUT INDICATOR: Shows the present heat output setting.

8.HEAT LEVEL ADJUSTMENT: When pressed, will change the heat setting of the unit from low to high.

AUTOMATIC SAFETY FEATURES OF YOUR PELLET STOVE:

A.The stove will shut off when the fire goes out and the exhaust temperature drops below 120°F (49°C).

B.The stove has a high temperature safety switch. If the temperature on the hopper reaches 200°F (93°C), the auger will automatically stop and the stove will shut down when the exhaust temperature cools. If this happens, call your local dealer to reset the 200°F (93°C) high limit switch. ALSO FIND

THE REASONS WHY THE UNIT OVERHEATED.

6

Image 6 Contents
Evolution Table of Contents Introduction I. Pellet StandardsStore pellets at least 36 1 m away from the pellet stove USE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Reasons WHY the Unit Overheated Operating InstructionsThermostat / Switch Mode Initial START-UP See aboveBurner POT and Liner 2-3 days Routine Cleaning and MaintenanceTools Required to Clean Unit Heat Exchanger Tubes 2-3 daysFresh AIR Intake biannually Door Glass Cleaning 2-3 daysASH PAN weekly Exhaust Passages biannuallyDoor Glass Replacement Post Season CLEAN-UPCleaning Plated Surfaces Brick PanelInstallation Screws to take out to remove stove from palletDimensions of EF5 Minimum Alcove depth Inches Installing Hearth Pad Pedestal onto EF5 Crawlspace, narrow Walkway Closely Exhaust Fresh Air Intake Page Venting horizontally with rise Inside Vertical Installation Outside Vertical Installation Through vent hole Exterior Blower KitThrough Wall Installation with Exterior Blower Kit EF5 If you wish to adjust the slider damper externally not REQUIRED, please follow the instructions belowSlider Damper Located Behind Left Side panel. To open Special NotesDo not TroubleshootingStove will not operate when hot What to do if200 F 93 C high limit temperature sensor has tripped Exhaust motor will not function normallyLight # 2 on Heat output bar flashing Ignitor- the pellets will not light Control settings Heat Level has no effect on the fireConvection blower will not function normally Stove keeps going outWiring Diagram 5V DCParts List Reference Number Description Part Number50-1085 Parts Diagram Components SteelDiagramParts Warranty To the DealerTo the Distributor Installation Data Sheet Name of Owner Address