Troubleshooting

DO NOT:

Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures.

Do not remove from the firebox any screws without penetrating oil lubrication.

WHAT TO DO IF:

1.The stove will not start.

2.The stove will not operate when hot.

3.The exhaust blower will not function normally.

4.Light # 2 on Heat output bar flashing.

5.Auger light flashes but auger motor does not turn at all

6.The 200 °F (93 °C) high limit temperature sensor has tripped.

7.The convection blower will not function normally.

8.Igniter- the pellets will not light.

9.Control settings (Heat Level) has no effect on the fire.

10.The stove keeps going out.

*NOTE: All troubleshooting procedures should be carried out by qualified technicians or installers.

1. The stove will not start.

üMake sure the stove is plugged in and the wall outlet is supplying power..

üIf the Control Board has been placed in the ON /OFF thermostat mode, then turn the thermostat up to call for heat.

üCheck the Heat Level Indicator. - If the # 2 light is flashing (see the # 2 light is flashing) üCheck the fuses on the circuit board (see “Troubleshooting - Fuses”).

üIf the unit still does not start, contact your local service dealer for service.

2. The stove will not operate when hot.

üCheck the Heat Level Indicator if a fire is not detected, or if the fire has gone out the #3 light will flash because the Exhaust Temperature Sensor’s contacts have opened.

üCheck the hopper for fuel.

üIncorrect air damper setting. - Excessive air may consume the fire too quickly before the next drop of fuel, leaving completely unburned fuel in the burn pot liner. - Insufficient air will cause build up, further restricting the air flow through the Burn Pot Liner. This in turn will cause the fuel to burn cold and very slowly. Fuel may build up and smother the fire. In this case clean the burn pot. (NOTE: unit may require a change to the vent system or installation of fresh air to correct Air to Fuel ratio problems).

üCombustion Blower failure. - The Combustion Blower is not turning fast enough to generate the proper vacuum in the fire box. Visual Check – is the blower motor turning.

üCheck the Exhaust Blower voltage across the blower wires (>=114 V on #5 setting and >= 82 on #1 setting). – Replace the Circuit Board if the Voltage reading is less than 82 V. with a line voltage >115 V AC.

üCheck Vacuum levels in the exhaust channel by bypassing the Vacuum Switch, then remove the Vacuum hose from Vacuum Switch. Check exhaust vacuum readings by placing the open end of the Vacuum Hose on a Magnahelic Gauge (readings must be above .10” W.C. on low fire).

If the motor fails to reach a 0.10” W.C. readings, then replace the Combustion Blower.

27

Image 27
Contents Evolution Table of Contents Introduction I. Pellet StandardsStore pellets at least 36 1 m away from the pellet stove USE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Operating Instructions Reasons WHY the Unit OverheatedInitial START-UP See above Thermostat / Switch ModeHeat Exchanger Tubes 2-3 days Routine Cleaning and MaintenanceTools Required to Clean Unit Burner POT and Liner 2-3 daysExhaust Passages biannually Door Glass Cleaning 2-3 daysASH PAN weekly Fresh AIR Intake biannuallyBrick Panel Post Season CLEAN-UPCleaning Plated Surfaces Door Glass ReplacementScrews to take out to remove stove from pallet InstallationDimensions of EF5 Minimum Alcove depth Inches Installing Hearth Pad Pedestal onto EF5 Crawlspace, narrow Walkway Closely Exhaust Fresh Air Intake Page Venting horizontally with rise Inside Vertical Installation Outside Vertical Installation Exterior Blower Kit Through vent holeThrough Wall Installation with Exterior Blower Kit EF5 REQUIRED, please follow the instructions below If you wish to adjust the slider damper externally notSpecial Notes Slider Damper Located Behind Left Side panel. To openWhat to do if TroubleshootingStove will not operate when hot Do not200 F 93 C high limit temperature sensor has tripped Exhaust motor will not function normallyLight # 2 on Heat output bar flashing Stove keeps going out Control settings Heat Level has no effect on the fireConvection blower will not function normally Ignitor- the pellets will not light5V DC Wiring DiagramReference Number Description Part Number Parts List50-1085 Parts Diagram Components SteelDiagramParts Warranty To the DealerTo the Distributor Name of Owner Address Installation Data Sheet

C-10608 specifications

Enviro C-10608 is an innovative solution designed to address the increasing environmental concerns related to chemical waste management and pollution control. Leveraging state-of-the-art technologies and advanced material science, Enviro C-10608 provides a comprehensive approach to minimizing the ecological footprint of industrial operations.

One of the main features of Enviro C-10608 is its exceptional versatility. It can be utilized across various sectors, including manufacturing, oil and gas, and agriculture. This adaptability makes it a valuable asset for organizations looking to comply with stringent environmental regulations while improving their sustainability practices. By effectively treating and managing waste materials, Enviro C-10608 promotes circular economy principles and helps companies reduce their reliance on raw materials.

Moreover, Enviro C-10608 employs cutting-edge filtration technologies that enhance its performance significantly. Its advanced filtration system is designed to capture a wide range of contaminants, including heavy metals, toxins, and organic compounds, ensuring that discharged effluents meet or exceed environmental standards. This not only protects local ecosystems but also safeguards public health, making it an essential tool in modern waste management.

Another notable characteristic of Enviro C-10608 is its low energy consumption. The product is engineered to operate efficiently, reducing the overall carbon footprint associated with waste treatment processes. This energy efficiency is further complemented by its use of renewable energy sources, further enhancing its appeal to environmentally conscious organizations.

Additionally, Enviro C-10608 features real-time monitoring and reporting capabilities. This technological integration allows for the continuous assessment of treatment efficiency and compliance levels, ensuring that users can make informed decisions based on accurate data. The user-friendly interface simplifies the monitoring process, enabling companies to adapt their operations swiftly in response to changing environmental regulations.

Finally, Enviro C-10608 stands out for its commitment to safety and user-friendliness. Designed with straightforward installation and operation procedures, it minimizes downtime and training requirements for staff. The product’s materials are non-toxic and sustainable, promoting a healthier work environment.

In conclusion, Enviro C-10608 embodies a forward-thinking approach to waste management. With its versatile applications, advanced filtration technologies, energy efficiency, real-time monitoring, and commitment to safety, it is poised to become a cornerstone in the sustainable practices of industries worldwide.