Enviro C-10365, EG40 DV owner manual Assembly of Venting Kit

Page 17

Initial Installation

QUALIFIED INSTALLERS ONLY

19.Place a bead of high temperature silicone on the flue pipe and slide the flex liner over the collar, secure the flex liner with three (3) sheet metal screws evenly spaced.

20.Align all straight sections of pipe, slipping all joints together and installing with three (3) sheet metal screws evenly spaced.

21.Install the brass decorative rings around each joint making sure this decorative ring covers the sheet metal screws that secure each section of pipe together and secure to vent pipe in the slotted tab on the backside of the pipe so that the fastener would not be seen.

22.Secure the horizontal section of pipe to the inside finished collar by installing a screw in the tab on the inside finished collar. This will prevent the pipe from being disconnected at the vent terminal.

23.Light the appliance and ensure proper operation.

Wall thimble

Horizontal wall

fire stop

 

termination

 

Wall framing

Inside finished collar

 

Decorative

 

brass rings

 

Exhaust 4"

 

flex pipe

 

Combustion air

 

6 5/8" outer pipe

 

Flue pipe adaptor

 

Figure 23: Assembly of Venting Kit.

17

Image 17
Contents S H E R W O O D I N D U S T R I E S L T D EG40 DVGeneral Safety PrecautionsFor Your Safety Table of Contents This Enviro EG40 DV Fireplace Codes And ApprovalsVented GAS Fireplace Heater EG40 DV NG/LPG EG40 Exterior Dimensions SpecificationsQualified Installers only Initial InstallationVent restrictor ring Vent Pipe Types with Part Numbers Venting Terminals Cannot be Recessed Into a Wall or SidingCommon Vertical Installation High temperature Silicone Male Edge Outer pipe. Push Installing Horizontal Vent Termination Do not interfere with the structural integrity of the walls Feet Meters Roof Pitch Minimum HeightMulti-Story Vent Pipe Installation KIT Components Cut away of spacers on Flex Pipe Installation InstructionsAssembly of Venting Kit Assembly of Venting into a Class ‘A’ Chimney Wiring of a Thermostat Turn the unit off and remove the log set 50% turn down HI-LOW Regulator Pressure taps are located on the left side of the valve GAS Line ConnectionTo Test Valve Pressures Log Placement Secondary InstallationLog Placement with Embers What to do if YOU Smell GAS Water Never USE AN Open Flame for Leak TESTING. IfOperating Instructions Cleaning the Inside of the Firebox Routine Maintenance and ServiceCleaning Plated Surfaces Opening the DoorProblem Possible Cause Solution Trouble ShootingParts List Parts List Parts Diagram Chassis Parts Diagram Gas Tray & Door To the Distributor WarrantyInstallation Data Sheet