Initial Installation

QUALIFIED INSTALLERS ONLY

INSTALLATION INSTRUCTIONS:

1.Decide on a location for the unit that will meet any or all local code requirements. Refer “Planning Your Installation” and “Clearances to Combustibles”.

2.Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing pipes are in the way of the venting system as it passes through the wall. If obstructions are found in the wall it may be necessary to adjust the location of the appliance.

3.Set the appliance in the desired location. Temporarily place a 24” (61 cm) section with the non-crimped end on the unit

4.Install the 90° elbow onto the vertical pipe on the stove pointing in the direction that the vent will exit the structure.

5.Project a level line from the center point of the elbow. Using this center point, scribe a 10” (25.4 cm) hole or square on the wall. Cut the hole out on both the interior and exterior wall surface.

6.Frame the hole as shown in Figure 9.

7.Install the wall thimble and secure the thimble to the inner wall surface.

8.With the appliance still in place install the 24” (61 cm) horizontal section on the elbow and let this section of pipe protrude through the exterior surface. Mark the pipe so that when it is cut it will be flush with the exterior wall.

9.Dismantle the outer pipe sections.

10.Remove the 4” (10 cm) flue collar from the unit and remove any loose sealant. Install the new Ø 4” (10 cm) by 5” (12.5 cm) flue collar provided in this kit.

11.Stretch the liner out. Attach the flexible liner to the vent termination cap by placing a small bead of high temperature silicone on the vent termination and slide the flex liner onto the vent terminal and secure with three (3) sheet metal screws evenly spaced.

12.Dress the flex liner through the wall thimble and attach the vent terminal to the outside of the house using four (4) wood screws provided. The use of non-hardening mastic should be used around the vent to ensure a watertight seal.

����

�������

Figure 21: Cut away of spacers on Flex Pipe.

13.Install two (2) wire spacer around the flex pipe. Slide the horizontal section of pipe over the flexible liner. Ensure the wire spacers are positioned at either end of the pipe (refer to Figure 21 and 22).

14.Install the horizontal section of pipe through the wall thimble, ensure that this portion of pipe slides onto the vent termination cap.

15.Slide the inside finished collar over the horizontal section of pipe and secure to wall using the screw provided.

16.Slide the 90° elbow over the flex pipe. Do not slip the outer sections of pipe together, you will require some movement in these pipe section in order to secure the flex pipe to the flue outlet on the appliance.

17.Stretch the flex liner to a length long enough to ensure the flex liner can be easily connected to the flue outlet of the appliance.

18.Install the remaining wire spacers over the flexible liner and install the vertical section of pipe. Ensure the wire spacers are positioned at either end of the pipe (refer to Figure 21 and 22).

Figure 22: Top view of spacers on Flex

Pipe.

16

Image 16
Contents EG40 DV S H E R W O O D I N D U S T R I E S L T DFor Your Safety Safety PrecautionsGeneral Table of Contents Vented GAS Fireplace Heater EG40 DV NG/LPG Codes And ApprovalsThis Enviro EG40 DV Fireplace Specifications EG40 Exterior DimensionsInitial Installation Qualified Installers onlyVent restrictor ring Venting Terminals Cannot be Recessed Into a Wall or Siding Vent Pipe Types with Part NumbersCommon Vertical Installation High temperature Silicone Male Edge Outer pipe. Push Installing Horizontal Vent Termination Do not interfere with the structural integrity of the walls Roof Pitch Minimum Height Feet MetersMulti-Story Vent Pipe Installation KIT Components Installation Instructions Cut away of spacers on Flex PipeAssembly of Venting Kit Assembly of Venting into a Class ‘A’ Chimney Wiring of a Thermostat Turn the unit off and remove the log set 50% turn down HI-LOW Regulator To Test Valve Pressures GAS Line ConnectionPressure taps are located on the left side of the valve Secondary Installation Log PlacementLog Placement with Embers Operating Instructions Water Never USE AN Open Flame for Leak TESTING. IfWhat to do if YOU Smell GAS Routine Maintenance and Service Cleaning the Inside of the FireboxCleaning Plated Surfaces Opening the DoorTrouble Shooting Problem Possible Cause SolutionParts List Parts List Parts Diagram Chassis Parts Diagram Gas Tray & Door Warranty To the DistributorInstallation Data Sheet