Enviro EG40 DV, C-10365 Routine Maintenance and Service, Opening the Door, To Replace Door

Page 26

Routine Maintenance and Service

Periodically check to ensure that your direct vent system is clean.

Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue with no or very small yellow tips.

OPENING THE DOOR

Turn unit off and wait until the appliance has cooled down.

1.Open the right hand hinged side flap, which will expose a door fastener. Using a 1⁄2” wrench, loosen the fastener.

2.Due to the shape of the bay window door. You must also open the left-hand side flap before attempting to open the door.

3.If the door must be removed open the door and lift the door pins out of the hinges (see figure 39).

���� ��

��� ������ �����

Figure 39: Removing the Door.

4. Ensure the door is properly fastened after cleaning before attempting to re-light the appliance.

CLEANING THE GLASS (Allow the glass to cool before cleaning.)

It will be necessary to clean the ceramic glass periodically. During a cold start up, condensation will sometimes form on the glass. This is a normal condition with all gas fireplaces and stoves. However, this condensation can allow dust and lint to cling to the glass surface. Initial paint curing of the appliance can leave behind a slight film on the glass. This is a temporary problem. It is therefore recommended that the glass be cleaned initially after about the first four hour of use.

Depending upon the amount of use, cleaning should be required no more than two or three times per season.

To clean the door, use a mild glass cleaner and a soft cloth or a glass cleaner available from your Enviro dealer. Abrasive cleaners will damage the glass.

TO REPLACE DOOR

The glass in this appliance is an integral part of the door assembly. If the glass is damaged or broken a replacement inner door with glass assembly must be purchased.

The glass in this appliance is ceramic. If the glass is damaged or broken a factory door with glass replacement must be used.

Remove the door with glass, a new door assembly must be purchased from an ENVIRO dealer (part #: EC-063).

Do not use a substitute materials; it will void the warranty.

CLEANING THE INSIDE OF THE FIREBOX

1.Turn off the unit and allow it to cool down completely.

2.Remove the logs carefully from the firebox. Gently remove the embers and place on a piece of paper towel, until ready to replace.

3.Vacuum the bottom of the firebox thoroughly. Carefully clean off any dust on the logs and remove any lint from the main burner and pilot burner.

4.After carefully replacing the log and embers in their correct positions (see Secondary Installation - Installation of Log Set and Embers), and the door has been resealed, re-light the pilot, following the instructions on the lighting label attached to the unit.

CLEANING PLATED SURFACES:

It is important to note that fingerprints and other marks can leave a permanent stain on plated finishes. To avoid this, give the face a quick wipe with denatured alcohol on a soft cloth BEFORE lighting the fireplace. Never clean the face when it is not cool. Do not use other cleaners as they may leave a residue, which can become permanently etched into the surface.

26

Image 26
Contents EG40 DV S H E R W O O D I N D U S T R I E S L T DGeneral Safety PrecautionsFor Your Safety Table of Contents This Enviro EG40 DV Fireplace Codes And ApprovalsVented GAS Fireplace Heater EG40 DV NG/LPG Specifications EG40 Exterior DimensionsInitial Installation Qualified Installers onlyVent restrictor ring Venting Terminals Cannot be Recessed Into a Wall or Siding Vent Pipe Types with Part NumbersCommon Vertical Installation High temperature Silicone Male Edge Outer pipe. Push Installing Horizontal Vent Termination Do not interfere with the structural integrity of the walls Roof Pitch Minimum Height Feet MetersMulti-Story Vent Pipe Installation KIT Components Installation Instructions Cut away of spacers on Flex PipeAssembly of Venting Kit Assembly of Venting into a Class ‘A’ Chimney Wiring of a Thermostat Turn the unit off and remove the log set 50% turn down HI-LOW Regulator Pressure taps are located on the left side of the valve GAS Line ConnectionTo Test Valve Pressures Secondary Installation Log PlacementLog Placement with Embers What to do if YOU Smell GAS Water Never USE AN Open Flame for Leak TESTING. IfOperating Instructions Cleaning Plated Surfaces Routine Maintenance and ServiceCleaning the Inside of the Firebox Opening the DoorTrouble Shooting Problem Possible Cause SolutionParts List Parts List Parts Diagram Chassis Parts Diagram Gas Tray & Door Warranty To the DistributorInstallation Data Sheet