Enviro EF4 owner manual Vent surfaces can

Page 15

Installation

VENT TERMINATION REQUIREMENTS:

IT IS RECOMMENDED THAT YOUR PELLET STOVE BE INSTALLED BY AN AUTHORIZED DEALER/INSTALLER. Table 1: Use in conjunction with Figure 13 for allowable exterior vent termination locations.

Letter

Minimum Clearance

Description

 

 

 

A

24 in (61 cm)

Above grass, top of plants, wood, or any other combustible materials.

 

 

 

B

48 in (122 cm)

From beside/below any door or window that may be opened.

 

 

 

C

24 in (61 cm)

From above any door or window that may be opened.

 

 

 

D

24 in (61 cm)

To any adjacent building, fences and protruding parts of the structure.

 

 

 

E

24 in (61 cm)

Below any eave or roof overhang

 

 

 

F

12 in (30 cm)

To outside corner.

 

 

 

G

12 in (30 cm)

To inside corner, combustible wall (vertical and horizontal terminations).

 

 

 

H

3 ft (91 cm) within a height of 15 ft (4.5

To each side of center line extended above natural gas or propane meter/regulator assembly or

 

m) above the meter/regulator assembly

mechanical vent.

 

 

 

I

3 ft (91 cm)

From any forced air intake of other appliance

 

 

 

J

12 in (30 cm)

Clearance to non-mechanical air supply inlet to building, or the combustion air inlet to any appliance.

 

 

 

K

24 in (61 cm)

Clearance above roof line for vertical terminations.

 

 

 

L

7 ft (2.13 m)

Clearance above paved sidewalk or paved driveway located on public property.

 

 

 

1.Do not terminate the vent in any enclosed or semi-enclosed areas such as a carport, garage, attic, crawlspace, narrow walkway, closely fenced area, under a sundeck or porch, or any location that can build up a concentration of fumes such as stairwells, covered breezeway, etc.

2.Vent surfaces can

 

 

 

 

 

 

K

G

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

D

F

 

Opens

B

C

G

 

 

 

 

G

 

 

Opens

 

 

 

 

 

 

 

 

 

 

 

B

 

A

 

I

Opens

L

 

 

 

 

 

 

 

 

 

Termination Cap

G

Gas Meter

H

 

 

 

Air Supply Inlet

Restriction Zone

 

 

 

 

 

 

(Termination not allowed)

 

Figure 13: Use in conjunction with Table 1 for allowable exterior vent termination locations.

become hot enough to cause burns if touched by children. Non-combustible shielding or guards may be required.

3.Termination must exhaust above the inlet elevation. It is recommended that at least five feet of vertical pipe be installed outside when the appliance is vented directly through a wall, to create some natural draft to prevent the possibility of smoke or odor during appliance shut down or power failure. This will keep exhaust from causing a nuisance or hazard from exposing people or shrubs to high temperatures. In any case, the safest and preferred venting method is to extend the vent through the roof vertically.

4.Distance from the bottom of the termination and grade is 12” (30 cm) minimum. This is conditional upon the plants and nature of grade surface. The exhaust gases are hot enough to ignite grass, plants and shrubs located in the vicinity of termination. The grade surface must not be lawn.

5.If the unit is incorrectly vented or the air to fuel mixture is out of balance, a slight discoloration of the exterior of the house might occur. Since these factors are beyond the control of Sherwood Industries Ltd, we grant no guarantee against such incidents.

6.When installing an FPI the chimney must be fully lined. Unless the chimney’s inside diameter is less than 6” (15 cm) around or has a cross section area of 28 inches² (180.6 cm²), we strongly recommend lining all masonry chimneys.

NOTE: Venting terminals shall not be recessed into walls or siding.

15

Image 15
Contents EF4 Table of Contents Store pellets at least 36 1 m away from the pellet stove IntroductionUSE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Reasons WHY the Unit Overheated Operating InstructionsSpecial Notes Stove. When cool enough, the stove will shut down Exhaust Passages 2-3 days Routine Cleaning and MaintenanceTools Required to Clean Unit Burn POT and LinerFreestanding ASH PAN Insert ASH RemovalExhaust Vent season Installation of firebox backingPost Season CLEAN-UP Cleaning Plated SurfacesScrews to take out to remove stove from pallet InstallationDimensions of EF4 Freestanding Minimum solid fuel burning fireplace opening Height 211⁄8 Freestanding Pedestal Vent surfaces can Exhaust Fresh Air Intake Unit on it Locate the center of the exhaust Is the recommended installation set up Inside Vertical Installation Outside Vertical Installation Freestanding hearth mount installation overview Masonry fireplace installation Surround Panel, back view RemovalInstall Plated Door a Cleaning the Plated Door aRemove Painted Door a What to do if TroubleshootingStove will not operate when hot √ Check the hopper for fuel Do notConvection blower will not function normally Exhaust motor will not function normallyTroubleshooting Stove keeps going out Dial-a-fire has no effect on the firePotentiometer Readings Stove will not shut downWiring Diagram Reference Number Description Part Number Part ListLog set Part List -Options DiagramComponentsPart Part Diagram Steel Warranty To the DistributorFor the do-it-yourself Individual Name of Owner Address Installation Data Sheet