Enviro EF4 owner manual Is the recommended installation set up

Page 19

Installation

10.The pipe must extend at least 12” (30 cm) away from the building. If necessary, bring another length of pipe (PL type) to the outside of the home to connect to the first section. Do not forget to place high temperature silicone around the pipe that passes through the thimble.

11.Install a vertical pipe, or if all requirements for direct venting are met, install vent termination. The stainless steel cap termination manufactured by the vent manufacturer is recommended. However, when the vent terminates several feet above ground level and there are no trees, plants, etc. within several feet, a 45° elbow can be used as termination. The elbow must be turned down to prevent rain from entering.

NOTE:

Some horizontal through wall installations may require a “T” and 3 to 5 feet (91 to 152 cm) of vertical pipe outside the building to help naturally draft in the unit.

This may be required if a proper burn cannot be maintained, after the stove has been tested and the airflow set.

This is due to the back pressure in the exhaust caused by airflow around the structure.

All sections of pipe must have three (3) screws evenly spaced and all horizontal and vertical vent sections located within the house must have a bead of high temperature silicone installed on the male end of the pipe before installation to create a gas tight seal.

THROUGH WALL WITH VERTICAL RISE AND HORIZONTAL TERMINATION INSTALLATION - FREESTANDING:

A 45° elbow with a rodent screen may be used in place of the termination cap (or stainless steel termination hood).

Figure 21 is the recommended installation set up.

Figure 22 is the installation to use if there is a concrete or retaining wall in line with exhaust vent on a pellet stove. The termination must be 12” (30 cm) from the outside wall and 12” (30 cm) above the ground.

Termination cap

 

90° elbow

 

Wall framing

 

Vertical section

 

of vent pipe

Wall strap

Horizontal frame

 

for thimble

 

 

Clean

 

out tee

 

Wall thimble

ENVIRO EF4

 

Figure 21: Venting horizontally with rise.

Horizontal frame

 

for thimble

Termination cap

Wall thimble

 

90° elbow

 

Wall framing

 

Vertical section

 

of vent pipe

 

 

Concrete Wall

ENVIRO EF4

Clean out tee

Figure 22: Venting with concrete wall behind unit .

19

Image 19
Contents EF4 Table of Contents Store pellets at least 36 1 m away from the pellet stove IntroductionUSE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Operating Instructions Reasons WHY the Unit OverheatedSpecial Notes Stove. When cool enough, the stove will shut down Exhaust Passages 2-3 days Routine Cleaning and MaintenanceTools Required to Clean Unit Burn POT and LinerFreestanding ASH PAN Insert ASH RemovalExhaust Vent season Installation of firebox backingPost Season CLEAN-UP Cleaning Plated SurfacesScrews to take out to remove stove from pallet InstallationDimensions of EF4 Freestanding Minimum solid fuel burning fireplace opening Height 211⁄8 Freestanding Pedestal Vent surfaces can Exhaust Fresh Air Intake Unit on it Locate the center of the exhaust Is the recommended installation set up Inside Vertical Installation Outside Vertical Installation Freestanding hearth mount installation overview Masonry fireplace installation Surround Panel, back view RemovalCleaning the Plated Door a Install Plated Door aRemove Painted Door a What to do if TroubleshootingStove will not operate when hot √ Check the hopper for fuel Do notConvection blower will not function normally Exhaust motor will not function normallyTroubleshooting Stove keeps going out Dial-a-fire has no effect on the firePotentiometer Readings Stove will not shut downWiring Diagram Reference Number Description Part Number Part ListLog set Part List -Options DiagramComponentsPart Part Diagram Steel To the Distributor WarrantyFor the do-it-yourself Individual Name of Owner Address Installation Data Sheet