Enviro EF4 owner manual Inside Vertical Installation

Page 20

Installation

INSIDE VERTICAL INSTALLATIONS - FREESTANDING:

1. Choose a stove location that is ideal. See the section “DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE.”

2.Place a non-combustible hearth pad where necessary.

3.Place the unit on the hearth pad (if installed on a carpeted surface) and space the unit in a manner so when the pellet vent is installed vertically, it will be 3” (7.6 cm) away from a combustible wall.

4.Locate the center of the fresh air intake pipe on the unit. Match that center with the same point on the wall and cut a hole about 1 5⁄8” (41

mm)in diameter.

5.Install the fresh air intake pipe.

6.Install the tee with clean out.

7.Install the pellet vent upward from there. When you reach the ceiling, make sure that the vent goes through the ceiling fire stop. Maintain a 3” (7.6 cm) distance to combustibles and keep attic insulation away from the vent pipe. Maintain an effective vapor barrier.

8.Finally, extend the pellet vent to go through the roof flashing.

9.Ensure that the rain cap is approximately 36” (915 mm) above the roof.

 

Rain cap

 

Flashing

 

24"

 

(61 cm)

3" (7.5 cm)

 

clearance

 

Use wall thimble

or ceiling firestop

 

3"

 

(7.5 cm)

 

Tee with

 

cleanout

6"

6"

(15 cm)

 

(15 cm)

 

Fresh air

 

intake

Non-combustible

Existing floor

floor protection.

(combustible)

Figure 23: Inside Vertical Installation.

OUTSIDE VERTICAL INSTALLATIONS - FREESTANDING:

To accomplish a outside vertical pipe installation, follow steps 1 through 5 in the “INSIDE VERTICAL INSTALLATIONS

-FREESTANDING” section and then finish it by performing the following (refer to Figure 24).

1.Install a tee with clean out on the outside of the house.

2.Install PL vent upward from the tee. Make sure that you install support brackets to keep the vent straight and secure.

3.Install ceiling thimble and secure the flashing as you go through the roof.

4.Ensure that the rain cap is approximately 36” (91.5 cm) above the roof.

20

Image 20
Contents EF4 Table of Contents Introduction Store pellets at least 36 1 m away from the pellet stoveUSE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Special Notes Reasons WHY the Unit OverheatedOperating Instructions Stove. When cool enough, the stove will shut down Routine Cleaning and Maintenance Tools Required to Clean UnitBurn POT and Liner Exhaust Passages 2-3 daysInsert ASH Removal Freestanding ASH PANInstallation of firebox backing Post Season CLEAN-UPCleaning Plated Surfaces Exhaust Vent seasonInstallation Screws to take out to remove stove from palletDimensions of EF4 Freestanding Minimum solid fuel burning fireplace opening Height 211⁄8 Freestanding Pedestal Vent surfaces can Exhaust Fresh Air Intake Unit on it Locate the center of the exhaust Is the recommended installation set up Inside Vertical Installation Outside Vertical Installation Freestanding hearth mount installation overview Masonry fireplace installation Removal Surround Panel, back viewRemove Painted Door a Install Plated Door aCleaning the Plated Door a Troubleshooting Stove will not operate when hot √ Check the hopper for fuelDo not What to do ifExhaust motor will not function normally Convection blower will not function normallyTroubleshooting Dial-a-fire has no effect on the fire Potentiometer ReadingsStove will not shut down Stove keeps going outWiring Diagram Part List Reference Number Description Part NumberLog set Part List -Options DiagramComponentsPart Part Diagram Steel For the do-it-yourself Individual WarrantyTo the Distributor Installation Data Sheet Name of Owner Address