Harman Stove Company P61A-2 Trouble-Shooting, Helpful Hints, Fuel, Cleaning Burn Pot

Page 22

P61A-2 Trouble-Shooting

FEEDER DOES NOT FEED

 

5. Power failure or blown fuse.

 

 

1. No pellets in hopper.

SMOKE IS VISIBLE COMING OUT OF VENT

2. Firebox draft may be too low for low draft pressure

 

1. Air-fuel ratio is too rich.

switch in feeder circuit to operate. Check for closed

 

A. Feed rate too high.

doors, loose or missing gasket on doors or hopper lid,

 

B. Draft too low caused by a gasket leak.

faulty pressure switch.

 

 

3. Feed motor will not run until ESP

LOW HEAT OUTPUT

senses 165 deg. F. Maybe you did not put

 

1. Feed rate too low

enough pellets in the burn pot before lighting the fire.

 

2. Draft too low because of gasket leak.

4. Something is restricting flow in the hopper or caus-

 

3. Poor quality or damp pellets

ing the slide plate to stick.

 

4. Combination of 1. and 2.

5. Feed motor has failed.

 

 

 

 

PARTIALLY BURNED PELLETS

 

Helpful Hints

1. Feed rate too high.

 

2. Draft too low. (Check burn pot clean out slide and

 

Cleaning Burn Pot

 

Whenever your stove is not burning, take the op-

door gasket).

 

 

portunity to scrape the burn pot to remove carbon

3. Burn pot or heat exchanger tubes may need to be

 

 

buildup. A vacuum cleaner is handy to remove the resi-

cleaned.

 

 

due. Be sure the stove is cold if you use a vacuum.

4. Combination of all the above.

 

 

Carbon buildup can be scraped loose with the fire

5. #6 status blink: A 6 blink control board status indi-

 

 

burning using the special tool provided with your stove.

cation is caused by poor or incomplete combustion.

 

 

Scrape the floor and sides of the burn pot. The carbon

TheAutomatic Ignition circuit board has the ability to

 

 

will be pushed out by the incoming fuel. Always wear

track the combustion through feed settings and ESP

 

 

gloves to do this.

temperatures. When the control board has calculated

 

poor or incomplete combustion it will shut down the

 

Removing Ashes

unit as a safety feature. (Poor or incomplete combus-

 

 

Turn the Temp Dial to number 1 approximately

tion is a contributer of creasote which may cause a

 

 

30 minutes before removing ashes. This will result in a

chimneyfire)

 

 

cooler stove and ash pan.

A 6 blink status may be caused by several things:

 

 

Maximum Feed Adjuster settings are not needed

1. Blocked or partially blocked flue.

 

 

in most cases. Operating in the normal range (#4) is

2. Blocked or partially blocked inlet air.

 

 

recommended when maximum heat output is not re-

a. backdraft damper on the inlet pipe may be stuck

 

 

quired. The ESP probe prevents the stove from being

closed.

 

 

over-fired.

b. if outside air is installed the inlet cover may be

 

 

Keep the stove free of dust and dirt.

blocked.

 

3. The air chamber under the burnpot may be filled

 

 

with fines and small bits of ash.

 

Fuel

4. The holes in the burnpot may be getting filled with

 

ash or carbon buildup.

 

Pellet fuels are put into 3 categories in terms of ash

5. Combustion blower fan blades may need cleaned.

 

content. Premium at 1% or less, Standard at 3% or less

6. No fuel in hopper.

 

and all others at 3% or more.

SMOKE SMELL

 

The P61A is capable of burning all 3 categories of

Seal the vent pipe joints and connection to stove with

 

pellets due to a patented feeder and burn pot system.

silicone.

 

It should be noted, however, that higher ash con-

FIRE HAS GONE OUT

 

tent will require more frequent ash removal and may

1. No pellets in hopper.

 

provide less BTU's per pound. Normally, standard and

2. Draft setting is too low.

 

high ash pellets cost less than premium pellets and can

3. Something is restricting fuel flow.

 

be cost effective when burned in the P61A.

4. Feed motor or draft motor has failed.

 

The moisture content must not exceed 8%. Higher

 

 

moisture will rob BTU's and may not burn properly.

22 P61A Pellet Stove

Image 22
Contents Installation & Operating Manual Safety NoticeP61A Pellet Stove Table of Contents Firebrick Assembly and InstallationUnpacking Flame GuideInstalling InstallationMobile Home Installation With outside air installed, 18î VentingVent Pipe VentingOutside Air #1 Preferred method #2 Preferred method#4 Installing into an existing chimney US only #5 Installing into an existing fireplace chimney US only#7 Installing into an existing chimney US and Canada Minimum flue vent configuration #8 Installing through the ceiling ventStove Temperature Mode Ignitor switch to AutoRoom Temperature Mode Shut-Down ProcedureP61A-2 Automatic Start UP Turn Mode Selector to OFFStarting First Fire Ignitor Switch to Manual P61A-2 Manual IGNITION/OPERATIONP61A-2 Manual Start UP Starting First Fire Ignitor Switch toMANUAL down positionFill hopper with pellets and remove ashes as required.1 Blinks In Igniter Auto. Mode Only Indicates Status light error messagesP61A-2 Automatic Ignition ESP Control P61A-2 Low Draft Voltage Adjustment Low Draft Voltage AdjustmentRoom Sensor and Rear Shield Installation Room Sensor Installation Rear ShieldsCleaning MaintenanceRemoving Ashes Soot and Fly Ash P61A-2 Maintenance Burn Pot Burn Pot Cleaning and MaintenanceHelpful Hints P61A-2 Trouble-ShootingCleaning Burn Pot FuelWeight 249 lbs Blower 135 cfm Feed Rate P61A-2 Feeder and SpecificationsSpecifications23.5 P61A FeederDoor Options Optional TrimSide Heat Shields OptionsHopper Extension P61A-2 Wiring Diagram P61A-2 Parts List Harman Gold Warranty Harman Gold Warranty Year Transferable Limited

P61A-2 specifications

The Harman Stove Company P61A-2 is a premier pellet stove that exemplifies modern design and efficient heating technology. Known for its high performance and user-friendly features, this model is a popular choice among homeowners seeking an eco-friendly heating solution.

One of the standout features of the P61A-2 is its impressive heating capacity. With the ability to produce up to 51,000 BTUs (British Thermal Units), it can effectively heat spaces of up to 2,800 square feet. This makes the stove suitable for both large living areas and open floor plans, ensuring consistent warmth during the chilly months.

The P61A-2 also boasts a sleek, contemporary design that fits seamlessly into various home decors. Available in several finishes, including classic black and rich bronze, it enhances the aesthetic appeal of any room. Its compact size allows for versatile installation options, whether it's in a corner or as a freestanding unit.

In terms of technology, the Harman P61A-2 features an advanced pellet feed system that maximizes efficiency and minimizes waste. This system ensures a steady supply of pellets to the burn pot, optimizing combustion and resulting in high efficiency ratings. The stove has an automatic ignition system, allowing users to easily start it with the push of a button, enhancing convenience and reducing the hassle often associated with traditional wood-burning stoves.

The stove is equipped with a unique heat exchanger and blower system that enhances heat distribution, ensuring warmth is circulated evenly throughout the room. Its adjustable variable-speed blower allows users to customize airflow, catering to their specific heating needs.

Additionally, the P61A-2 is designed with an easy-to-use control panel, providing options for temperature setting, operating modes, and diagnostics. This user-friendly interface allows for effortless operation, even for those new to pellet stoves.

Maintenance is simplified with the P61A-2, as it includes an easy-access clean-out door for quick ash disposal and a removable burn pot for thorough cleaning. The durable construction and high-quality materials ensure longevity, making the P61A-2 a reliable heating solution for years to come.

In summary, the Harman Stove Company P61A-2 combines powerful heating capabilities with innovative technology, a stylish design, and user-friendly features, making it a top choice for efficient home heating.