Harman Stove Company P61A-2 owner manual Venting, With outside air installed, 18î

Page 6

Venting

Requirements for Terminating the Venting WARNING: Venting terminals must not be re-

cessed into a wall or siding.

NOTE: Only PL vent pipe wall pass-throughs and fire stops should be used when venting through combustible materials.

NOTE: Always take into consideration the ef- fect the prevailing wind direction or other wind cur- rents will cause with flyash and /or smoke when plac- ing the termination.

In addition, the following must be observed: A. The clearance above grade must be a mini-

mum of 18".1

B. The clearance to a window or door that may be opened must be a minimum of 48" to the side, 48" below the window/door, and 12" above the win- dow/door.1

(with outside air installed, 18î )

C. A 12" clearance to a permanently closed window is recommended to prevent condensation on the window.

D. The vertical clearance to a ventilated soffit located above the terminal within a horizontal dis- tance of 2 feet (60 cm) from the center-line of the terminal must be a minimum of 18".

E. The clearance to an unventilated soffit must be a minimum of 12".

F. The clearance to an outside corner is 11" from center of pipe.

G. The clearance to an inside corner is 12".

H.A vent must not be installed within 3 feet (90 cm) above a gas meter/regulator assembly when measured from the horizontal center-line of the regu- lator.1

I. The clearance to service regulator vent outlet must be a minimum of 6 feet.1

J. The clearance to a non-mechanical air sup- ply inlet to the building or the combustion air inlet to any other appliance must be a minimum of 48î.1

K. The clearance to a mechanical air supply inlet must be a minimum of 10 feet.1

(with outside air installed, 6 feet )

L. The clearance above a paved sidewalk or a paved driveway located on public property must be a minimum of 7 feet.1,2

M. The clearance under a veranda, porch, deck or balcony must be a minimum of 12 inches.1,3

NOTE: The clearance to vegetation and other exterior combustibles such as mulch is 36î as mea- sured from the center of the outlet or cap. This 36î radius continues to grade or a minimum of 7 feet below the outlet.

1Certain Canadian and or Local codes or regu- lations may require different clearances.

2A vent shall not terminate directly above a side- walk or paved driveway which is located between two single †family dwellings and serves both dwell- ings.

3Only permitted if veranda, porch, deck, or bal- cony is fully open on a minimum of 2 sides beneath the floor.

NOTE: Where passage through a wall, or partition of combustible construction is desired, the installation shall conform to CAN/CSA-B365. (if in Canada)

Inside Corner

Detail

Fixed

 

 

Closed

Openable

Fixed

O p e n a b l e

 

Closed

 

 

6

 

V

= Vent terminal

A = Air supply inlet

= Area where terminal is not permitted

P61A

Pellet Stove

 

 

Image 6
Contents Installation & Operating Manual Safety NoticeP61A Pellet Stove Table of Contents Firebrick Assembly and InstallationUnpacking Flame GuideInstallation InstallingMobile Home Installation With outside air installed, 18î VentingVenting Vent PipeOutside Air #1 Preferred method #2 Preferred method#4 Installing into an existing chimney US only #5 Installing into an existing fireplace chimney US only#7 Installing into an existing chimney US and Canada Minimum flue vent configuration #8 Installing through the ceiling ventStove Temperature Mode Ignitor switch to AutoRoom Temperature Mode Shut-Down ProcedureTurn Mode Selector to OFF P61A-2 Automatic Start UPStarting First Fire Ignitor Switch to Manual P61A-2 Manual IGNITION/OPERATIONStarting First Fire Ignitor Switch toMANUAL down position P61A-2 Manual Start UPFill hopper with pellets and remove ashes as required.1 Status light error messages Blinks In Igniter Auto. Mode Only IndicatesP61A-2 Automatic Ignition ESP Control P61A-2 Low Draft Voltage Adjustment Low Draft Voltage AdjustmentRoom Sensor and Rear Shield Installation Room Sensor Installation Rear ShieldsMaintenance CleaningRemoving Ashes Soot and Fly Ash P61A-2 Maintenance Burn Pot Burn Pot Cleaning and MaintenanceHelpful Hints P61A-2 Trouble-ShootingCleaning Burn Pot FuelWeight 249 lbs Blower 135 cfm Feed Rate P61A-2 Feeder and SpecificationsSpecifications23.5 P61A FeederDoor Options Optional TrimOptions Side Heat ShieldsHopper Extension P61A-2 Wiring Diagram P61A-2 Parts List Harman Gold Warranty Harman Gold Warranty Year Transferable Limited

P61A-2 specifications

The Harman Stove Company P61A-2 is a premier pellet stove that exemplifies modern design and efficient heating technology. Known for its high performance and user-friendly features, this model is a popular choice among homeowners seeking an eco-friendly heating solution.

One of the standout features of the P61A-2 is its impressive heating capacity. With the ability to produce up to 51,000 BTUs (British Thermal Units), it can effectively heat spaces of up to 2,800 square feet. This makes the stove suitable for both large living areas and open floor plans, ensuring consistent warmth during the chilly months.

The P61A-2 also boasts a sleek, contemporary design that fits seamlessly into various home decors. Available in several finishes, including classic black and rich bronze, it enhances the aesthetic appeal of any room. Its compact size allows for versatile installation options, whether it's in a corner or as a freestanding unit.

In terms of technology, the Harman P61A-2 features an advanced pellet feed system that maximizes efficiency and minimizes waste. This system ensures a steady supply of pellets to the burn pot, optimizing combustion and resulting in high efficiency ratings. The stove has an automatic ignition system, allowing users to easily start it with the push of a button, enhancing convenience and reducing the hassle often associated with traditional wood-burning stoves.

The stove is equipped with a unique heat exchanger and blower system that enhances heat distribution, ensuring warmth is circulated evenly throughout the room. Its adjustable variable-speed blower allows users to customize airflow, catering to their specific heating needs.

Additionally, the P61A-2 is designed with an easy-to-use control panel, providing options for temperature setting, operating modes, and diagnostics. This user-friendly interface allows for effortless operation, even for those new to pellet stoves.

Maintenance is simplified with the P61A-2, as it includes an easy-access clean-out door for quick ash disposal and a removable burn pot for thorough cleaning. The durable construction and high-quality materials ensure longevity, making the P61A-2 a reliable heating solution for years to come.

In summary, the Harman Stove Company P61A-2 combines powerful heating capabilities with innovative technology, a stylish design, and user-friendly features, making it a top choice for efficient home heating.