Clarity B Vent .
Gas Heater Specifications
Tested to ANSI
| NATURAL GAS | PROPANE | |
Input Rating (Btu/hr) | 40,000 |
| 40,000 |
Min. Input Rating (Btu/hr) | 27,000 |
| 28,000 |
Injector Sizes (DMS) (front/center/rear | 47/56/39 | 56/71/53 | |
Manifold Pressure (in w.c./kPa) | 3.5/0.87 |
| 10.0/2.49 |
Minimum Manifold Pressure (in w.c./kPa) | 1.7/0.42 |
| 5.9/1.47 |
Minimum Inlet Pressure (in w.c./kPa) | 5.0/1.25 |
| 11.0/2.74 |
Maximum Output (Btu/hr) | 30,500 |
| 30,800 |
AFUE (seasonal efficiency; minimum venting) | 65.2% |
| 66.0% |
Steady State Efficiency (max. input, blower on High) | 78.2% |
| 79.7% . |
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION |
| ||
Unit to left sidewall | 9 in. | (230 mm) |
|
Unit to right sidewall | 9 in. | (230 mm) |
|
Unit corner to walls | 4 in. | (100 mm) |
|
Rear of unit to back wall | 3 in. | (75 mm) . |
|
(measured from rear of draft hood heat shield) |
|
|
|
Unit to alcove ceiling | 18 in. | (460 mm) |
|
Maximum alcove depth | 14 in. | (355 mm) |
|
Electrical Rating: 120 Volts, 60 Hz., Less than 1 Amp
Stove Weight: 234 lbs.
19