connecting the CORDSET
The Clarity
NOTE: The convection fan requires a 120 VAC supply for operation, but the heater can be operated without the fan as in the case of a power outage.
Plug the
WARNING: This heater is equipped with
a
Terminal strip for thermostat connec- tion
Rear view of Clarity
Connecting the
Optional Thermostat
If connecting the optional thermostat, it must be plugged into the terminal strip located on the left side near the bot- tom of the stove.
When installing a millivolt control sys - tem, use only a special low resistance thermostat.. Do not use a regular heating thermostat.
Be sure that all electrical connections are clean, free from corrosion, and tight. Inspect connections periodically to confirm that no corrosion has built up over time.
When properly installed and maintained, a millivolt control system should give many years of
It is important to use wire of a gauge proper for the length of the wire:
RECOMMENDED WIRE GAUGES
Maximum | Wire |
Length | Gauge |
100' | 14 |
60' | 16 |
40' | 18 |
25' | 20 |
15' | 22 |