CONNECTING THE HEATER
TO A GAS SUPPLY
Burn Only the Fuel for which the Heater is Equipped The Clarity
pane, but requires a dedicated burner system module for either fuel. The label on the burner system module indicates the fuel for which it is equipped. A second label, located near the rating plate, also indicates the fuel type.
NATURAL GAS
PROPANE
Making The Connection
The gas inlet is located at the bottom right rear of the stove. The inlet fitting is a 1/2" female flare flexible pipe.
A separate gas
The Clarity
The Clarity gas control valve must be in the OFF position during any pressure testing of the gas supply system at pres- sures equal to or less than 1/2 psig (3.5 kPa).
WARNING: To avoid pipe compounds from entering into the gas train, apply compounds only to the male pipe threads and only to the first two threads.
CAUTION: TESTALL JOINTS FOR LEAKS BEFORE OPERATING
Gas Pressure Requirements
Correct gas pressure and the use of a properly sized gas supply line are essential for the safe and efficient per- formance of this appliance. Make sure that the plumber or gas supplier checks the gas supply line and gas pressure at installation.
NOTE: Improper gas pressure can affect heater perfor- mance, flame color, or cause pilot outage.
Natural Gas:
Maximum inlet pressure 7.0" w.c. (1.74 kPa). Minimum inlet pressure 5.0" w.c. (1.25 kPa). Gas manifold pressure 3.5" w.c. (0.87 kPa)
LPG Gas:
Maximum inlet pressure 13" w.c. (3.24 kPa). Minimum inlet pressure 11" w.c. (2.74 kPa). Gas manifold pressure 10" w.c. (2.49 kPa)
DO NOT USE THIS HEATER IF ANY PART HAS BEEN UNDER WATER OR EXPOSED TO MOISTURE CORROSION. IMMEDIATELY CALL A QUALlFlED
SERVICE TECHNICIAN TO INSPECT THE HEATER AND REPLACE ANY PART OF THE CONTROL SYS- TEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.
RECOMMENDED GAS PIPE DIAMETER
Pipe Length | Schedule 40 Pipe | Tubing, Type L | ||
(Feet) | Inside Diameter | Outside Diameter | ||
|
|
|
|
|
| N.G. | L.P. | N.G. | L.P. |
|
|
|
|
|
1/2" | 3/8" | 1/2" | 3/8" | |
| 1.3 cm | 1.0 cm | 1.3 cm | 1.0 cm |
|
|
|
|
|
1/2" | 1/2" | 5/8" | 1/2" | |
| 1.3 cm | 1.3 cm | 1.6 cm | 1.3 cm |
|
|
|
|
|
1/2" | 1/2" | 3/4" | 1/2" | |
| 1.3 cm | 1.3 cm | 1.6 cm | 1.3 cm |
|
|
|
|
|
3/4" | 1/2" | 7/8" | 3/4" | |
| 2.0 cm | 1.3 cm | 2.3 cm | 2.0 cm |
|
|
|
|
|
NOTE: NEVER USE PLASTIC PIPE. CHECK TO CONFIRM WHETHER YOUR LOCAL CODES ALLOW COPPER TUBING
OR GALVANIZED PIPE.
Whether or not you have installed a conversion kit, fill out the installer fuel label, on the stove, or the one that was included with the conversion kit, and affix it to the stove in the appropriate location.