Harman Stove Company manual Trouble-Shooting24, Helpful Hints, Fuel, Cleaning Burn Pot

Page 24

Trouble-Shooting24

FEEDER DOES NOT FEED

1.No pellets in hopper.

2.Firebox draft may be too low for low draft pres- sure switch in feeder circuit to operate. Check for closed doors, loose or missing gasket on doors or hopper lid, faulty pressure switch.

3.Feed motor will not run until ESP

senses 165 deg. F. Maybe you did not put enough pellets in the burn pot before lighting the fire.

4.Something is restricting flow in the hopper or causing the slide plate to stick.

5.Feed motor has failed.

PARTIALLY BURNED PELLETS

1.Feed rate too high.

2.Draft too low. (Check burn pot clean out slide and door gasket).

3.Burn pot or heat exchanger tubes may need to be cleaned.

4.Combination of all the above.

5.#6 status blink: A 6 blink control board status indication is caused by poor or incomplete com- bustion. The Advance Automatic Ignition circuit board has the ability to track the combustion through feed settings and ESP temperatures. When the control board has calculated poor or incomplete combustion it will shut down the unit as a safety feature. (Poor or incomplete combustion is a contributer of creasote which may cause a chim- ney fire)

A 6 blink status may be caused by several things:

1.Blocked or partially blocked flue.

2.Blocked or partially blocked inlet air.

a.backdraft damper on the inlet pipe may be stuck closed.

b.if outside air is installed the inlet cover may be blocked.

3.The air chamber under the burnpot may be filled with fines and small bits of ash.

4.The holes in the burnpot may be getting filled with ash or carbon buildup.

5.Combustion blower fan blades may need cleaned.

6.Combustion intake assembly not properly latched.

7.No fuel in hopper.

SMOKE SMELL

Seal the vent pipe joints and connection to stove with silicone.

FIRE HAS GONE OUT

1.No pellets in hopper.

2.Draft setting is too low.

3.Something is restricting fuel flow.

4.Feed motor or draft motor has failed.

5.Power failure or blown fuse.

SMOKE IS VISIBLE COMING OUT OF VENT

1.Air-fuel ratio is too rich.

A.Feed rate too high.

B.Draft too low caused by a gasket leak.

LOW HEAT OUTPUT

1.Feed rate too low

2.Draft too low because of gasket leak.

3.Poor quality or damp pellets

4.Combination of 1. and 2.

Helpful Hints

Cleaning Burn Pot

Whenever your stove is not burning, take the op- portunity to scrape the burn pot to remove carbon buildup. A vacuum cleaner is handy to remove the resi- due. Be sure the stove is cold if you use a vacuum.

Carbon buildup can be scraped loose with the fire burning using the special tool provided with your stove. Scrape the floor and sides of the burn pot. The carbon will be pushed out by the incoming fuel. Always wear gloves to do this.

Removing Ashes

Turn the Temp Dial to number 1 approximately 30 minutes before removing ashes. This will result in a cooler stove and ash pan.

Maximum Feed Adjuster settings are not needed in most cases. Operating in the normal range (#4) is recommended when maximum heat output is not re- quired. The ESP probe prevents the stove from being over-fired.

Keep the stove free of dust and dirt.

Fuel

Pellet fuels are put into 3 categories in terms of ash content. Premium at 1% or less, Standard at 3% or less and all others at 3% or more.

The Accentra is capable of burning all 3 categories of pellets due to a patented feeder and burn pot system.

It should be noted, however, that higher ash con- tent will require more frequent ash removal and may provide less BTU's per pound. Normally, standard and high ash pellets cost less than premium pellets and can be cost effective when burned in the Accentra.

The moisture content must not exceed 8%. Higher moisture will rob BTU's and may not burn properly.

Image 24
Contents Installation & Operating Manual Harman Accentra-2 Pellet StoveTable of Contents IntroductionStove Temperature Mode Automatic Ignition/OperationAutomatic Start Up Starting First FireManual Stove Temperature Mode Ignitor Switch to Manual Room Temperature ModeIgnitor Switch to Manual Stove Temperature Mode Manual Ignition/OperationIgnitor Switch toMANUAL up position Manual Start UpMode Selector ESP ControlInstallation8 After the Installation is CompletedInstallation9 Adjustment of the rubber pad leveling feetMobile Home Installation After the Installation is CompletedLow Draft Voltage Adjustment Combustion Motor Speed Control Low draft only set pointRoom Sensor and Rear Shield Installation Room Sensor Installation Rear ShieldsVenting Vent PipeOutside Air Venting14 #1 Preferred method#2 Preferred method #4 Installing into an existing Chimney US only #5 Installing into an existing fireplace chimney US onlyVenting15 #7 Installing into an existing chimney US and Canada Venting16#8 Installing through the ceiling vent Minimumflue vent configurationVenting17 With outside air installed With outside air installed, 6 feetVenting18 Maintenance Cleaning Glass on View Door Maintenance Cleaning20 Cleaning Internal ComponentsFeeder Chamber To remove the feeder coverMaintenance Cleaning21 Maintenance Burn Pot Burn Pot Cleaning and MaintenanceAccentra Motor & Component Locations Trouble-Shooting24 Cleaning Burn PotHelpful Hints FuelSpecifications25 Accentra Wiring Diagram Accentra Feeder Parts Accentra Parts List 20-502221Harman Gold Warranty Harman Gold Warranty

2 specifications

Harman Stove Company 2 has earned a reputation as a leader in the hearth products industry, particularly known for its innovative approach to pellet stoves and inserts. Established with a commitment to quality and efficiency, Harman focuses on creating products that elevate comfort while being environmentally sustainable.

One of the standout features of Harman Stove Company 2 is its advanced heating technology. Their pellet stoves utilize a unique feed system that ensures consistent fuel delivery, which translates to reliable, even heat output. The integrated Smart Control technology allows users to easily adjust settings remotely, providing the convenience of controlling the stove from their smartphones.

Notably, Harman stoves come equipped with the exclusive Heat Management System (HMS), which helps to distribute warmth throughout the home effectively while optimizing fuel consumption. This system includes adjustable air intake and exhaust options that enhance efficiency, ensuring that less fuel is wasted and more heat is produced.

Durability is another hallmark of Harman's products. Each stove is constructed with high-quality materials, including rugged cast iron and heavy-gauge steel, designed to withstand the test of time while providing excellent heat retention. The company takes pride in its craftsmanship, offering stoves that not only perform exceptionally well but also boast a stylish appearance.

In terms of efficiency, Harman Stove Company 2 focuses on creating products with high efficiency ratings and low emissions. Many of its models are certified by the Environmental Protection Agency (EPA), showcasing their commitment to reducing the environmental impact. Harman's engineering innovations minimize particulate emissions, ensuring that customers can enjoy the warmth of their stove while being environmentally conscious.

Safety is also paramount; Harman stoves come with features such as automatic shutoff systems and heat-resistant glass, providing peace of mind for users. The company's dedication to safety is evident in its rigorous testing processes that ensure every product meets high safety standards.

Overall, Harman Stove Company 2 has successfully combined advanced technology, durable construction, and a focus on environmental stewardship to produce a line of heating solutions that cater to modern consumer needs. Offering reliability, efficiency, and style, Harman continues to be a trusted name in the industry, providing warmth and comfort in homes across the nation.