INSTALLATION
Combustion Air Supply
A 2” inside diameter metallic pipe, either flexible or rigid, may be attached to the inlet at the stove’s rear. A rodent guard (minimum ¼” wire mesh)/wind hood must be used at the terminus. All connections must be secured and airtight by either using the appropriately sized hose clamp and/or
NOTE: A COMBUSTION AIR SUPPLY IS REQUIRED FOR ALL MOBILE HOME
INSTALLATIONS, AND ALSO IN CONVENTIONAL HOME INSTALLATIONS IF THE
UNIT IS BEING INSTALLED IN A BASEMENT, SMALL ROOM, OR EXTREMELY
WELL INSULATED OR AIRTIGHT HOMES.
FOR MOBILE HOME INSTALLATIONS ONLY: For a mobile home
installation the stove must be connected to an outside source of combustion air per federal regulations. 2” inside diameter pipe may be used for the first 5 feet of combustion air supply run. From 5 to 10 feet use 2 ¾” inside diameter pipe.
NO COMBUSTION AIR SUPPLY MAY EXCEED 10 FEET OF EVL.
EVL (Equivalent Vent Length) for combustion air supply is calculated the same as for the venting or exhaust pipe.
SOURCES OF OUTSIDE COMBUSTION AIR
In fireplaces, outside air can be piped to the stove from the chimney top, fireplace ash clean out door, or a hole drilled through the back of the fireplace. The run of pipe for the combustion air supply should be as short as possible for the best performance.
For freestanding installations, this could be a hole in the floor near the stove rear terminating in a ventilated crawl space, or a hole in the wall behind the stove.
In tightly insulated homes, a closeable outside air register can be used.
WHEN OUTSIDE AIR IS NOT USED
If outside air is not used, it is important that the combustion air inlet is not restricted or blocked in any way.
Electrical Installation
This stove is provided with a
Voltage variations or incorrect polarity can lead to serious performance problems, especially related to the control board. The Breckwell electrical system is designed for 120V AC with no more than 5% variation. The polarity of the outlet should also be checked during installation. Most hardware stores carry an inexpensive polarity checker. Breckwell cannot accept responsibility for poor performance or damage due to inadequate voltage or incorrect polarity. If connected to an older,
3