MAINTENANCE

Chimney & Vent Cleaning

Creosote Formation – When wood is burned slowly, it produces tar and other organic vapors, which combine with moisture in the air and flue gases to form creosote. The creosote vapors condense in the relatively cool chimney and accumulates on the flue lining. If ignited, this creosote burns very hot, and may damage the chimney or lead to a catastrophic house fire. Despite their high efficiency, all wood-burning stoves in time, accumulate creosote which must be removed.

Fly Ash – This accumulates in the horizontal portion of an exhaust run. Though noncombustible, it may impede the normal exhaust flow. It should therefore be periodically removed.

Inspection and Removal – The chimney connector and chimney or pellet vent should be inspected regularly to determine if a creosote or fly ash build-up has occurred. At a minimum, it should be checked after every ton of fuel burned. If burning less than a ton per year the exhaust flue should still be inspected at least twice a burning season; once at the beginning of the season, and then again halfway through the season. If creosote has accumulated, it should be removed to reduce the risk of a chimney fire. Inspect the system at the stove connection and at the chimney top. Cooler surfaces tend to build creosote deposits quicker, so it is important to check the chimney from the top as well as from the bottom.

The creosote should be removed with a brush specifically designed for the type of chimney or pellet vent in use. A qualified chimney sweep can perform this service. It is also recommended that before each heating season the entire system be professionally inspected, cleaned and, if necessary, repaired.

To clean the chimney, detach the vent at the combustion blower transition where it is attached to the blower.

Recommended Maintenance Schedule

Use this as a guide under average-use conditions.

 

Daily

Weekly

Annually or per Ton

Burn Pot

Emptied

Cleaned

 

Glass

Wiped

Cleaned

 

Combustion Chamber

 

Brushed

 

Ashes

 

As Needed

 

Interior Chambers

 

Bi-Weekly

 

Combustion Blower Blades

 

 

Vacuumed / Brushed

Convection Blower Impeller

 

 

Vacuumed / Brushed

Vent System

 

 

Cleaned

Gaskets

 

 

Inspected

Hopper (end of season)

 

 

Emptied and vacuumed

Gasket around door and door glass should be inspected and repaired or replaced when necessary (see “REPLACEMENT PARTS”).

Removal and Replacement of Broken Door Glass

While wearing leather gloves (or any other gloves suitable for handling broken glass), carefully remove any loose pieces of glass from the doorframe. Dispose of all broken glass properly. Return the damaged door to your Breckwell Dealer for repair or replacement.

Neither the appliance owner nor any other unauthorized person(s) should replace the door glass. An authorized Breckwell dealer must perform all repairs involving door glass.

17

Image 21
Contents Breckwell Hearth Products Table of Contents Introduction Safety Precautions Specifications InstallationApproved Installations PreparationFloor Protection VentingEquivalent Vent Length EVL Combustion Air Supply Electrical InstallationExamples of Proper Installation Special Mobile Home RequirementsHorizontally Through Wall Vertically Into Existing Chimney System Vertically With New Chimney SystemVertically Into Existing Masonry Fireplace Installation Through Side of Masonry ChimneyProper Fuel OperationShelled Corn Wood PelletsLighting Directions First Time Use Pre-Start CheckGeneral Operation Control PanelStart-up Cycle Changing Heat LevelsShut Down Procedures Damper ControlBlower Speeds Opening the Fuel Hopper Lid Restarting a warm stoveError Codes Heat Level Light IndicatorsInstallation Optional ThermostatThermostat Operation Control Panel Reset Ash Disposal MaintenanceAsh Removal Vacuum UseCleaning Interior ChambersBlowers Recommended Maintenance Schedule Removal and Replacement of Broken Door GlassChimney & Vent Cleaning Stove Shuts Off and the Second Light Flashes Troubleshooting GuideStove Shuts Off and the Third Light Flashes Smoke Smell Coming Back Into The Home Convection Blower Shuts Off and Comes Back OnStove Will Not Feed Fuel, But Auger Light Does Come On Dirty Burn High Limit Switch Keeps Tripping Digital Circuit Board Timing RatesStir Motor Timing Rates Electrical Diagram Tool Lifetime Limited Warranty