Breckwell SP 6000 Vertically With New Chimney System, Vertically Into Existing Chimney System

Page 9

INSTALLATION

Vertically With New Chimney System

NOTE: FOLLOW L-VENT CHIMNEY MANUFACTURERS INSTRUCTIONS.

OPTION: To achieve a center vertical installation a 45º elbow and a clean-out tee can be used to offset the pipe from the exhaust outlet to the rear center of the stove.

Always maintain 3” clearance from combustible materials. When passing through additional floors or ceilings, always install fire stop spacer.

After lining up for hole in roof, cut either a round or square hole in roof, always 3” larger all the way around pipe. Install upper edge and sides of flashing under roofing materials, nail to the roof along upper edge. Do not nail lower edge. Seal nail heads with non-hardening waterproof mastic.

Apply non-hardening, waterproof mastic where the storm collar will meet the vent and flashing. Slide storm collar down until it sits on the flashing. Seal and install cap. Mobile home installations must use a spark arrester.

Vertically Into Existing Chimney System

The recommended installation method is to run the 3” or 4” L-Vent pipe up inside of the existing the chimney to termination.

FOLLOW GUIDELINES FOR EQUIVALENT VENT LENGTH.

5

Image 9
Contents Breckwell Hearth Products Table of Contents Introduction Safety Precautions Specifications InstallationApproved Installations PreparationFloor Protection VentingEquivalent Vent Length EVL Combustion Air Supply Electrical InstallationExamples of Proper Installation Special Mobile Home RequirementsHorizontally Through Wall Vertically Into Existing Chimney System Vertically With New Chimney SystemVertically Into Existing Masonry Fireplace Installation Through Side of Masonry ChimneyProper Fuel OperationShelled Corn Wood PelletsLighting Directions First Time Use Pre-Start CheckGeneral Operation Control PanelStart-up Cycle Changing Heat LevelsShut Down Procedures Damper ControlBlower Speeds Opening the Fuel Hopper Lid Restarting a warm stoveError Codes Heat Level Light IndicatorsInstallation Optional ThermostatThermostat Operation Control Panel Reset Ash Disposal MaintenanceAsh Removal Vacuum UseCleaning Interior ChambersBlowers Recommended Maintenance Schedule Removal and Replacement of Broken Door GlassChimney & Vent Cleaning Stove Shuts Off and the Second Light Flashes Troubleshooting GuideStove Shuts Off and the Third Light Flashes Smoke Smell Coming Back Into The Home Convection Blower Shuts Off and Comes Back OnStove Will Not Feed Fuel, But Auger Light Does Come On Dirty Burn High Limit Switch Keeps Tripping Digital Circuit Board Timing RatesStir Motor Timing Rates Electrical Diagram Tool Lifetime Limited Warranty