OPERATION
Control Panel Reset
It may become necessary to reset the control panel to the original factory specifications and settings. This could be due to erratic operation from the control panel, power fluctuations, or other reasons. It is easy to accomplish and will often correct any frustrating issues that you may be having.
In order to reset the control panel, follow the directions below:
∙ Turn the stove OFF (No lights on control board and allow the stove to cool until all fans are turned off) Unplug the stove and wait at least one full minute, then plug the unit back in.
∙Simultaneously press (briefly):
[AUGER FEED] + [HEAT LEVEL HIGH] + [FAN SPEED HIGH] + [FAN SPEED LOW]
∙** ALL RED/GREEN/YELLOW lights should blink ONCE
IMPORTANT: ALL lights should blink ONCE – if not, repeat the procedure.
Note: The SP6000 series 4100 board has 4 programs. These programs are currently used to adjust the combustion fan voltage to compensate for local electrical grid conditions. If the control board lights blink more than once (two, three, or four times), the board has been put into another program. If this occurs, repeat this RESET procedure again until the lights blink only once.
For further assistance, please call Breckwell Technical Support (toll free)
WHEN IN DOUBT, RESET THE BOARD
14