HOW TO USE

BE CAREFUL

Operate the heater in upright position only. Any other position could create hazardous situations!

ON/OFF Switches

800700

WATTS WATTS

With pilot lights ON, the heater is ON!

POWER ECONOMIZER

For more economical use, the Min. or Med. Watt switches may be used individually, after unit has reached the operating temperature.

1. LOCATION

Place the heater on the floor beneath the coldest window in the room or any desired location. Your heater will minimize the effect of cold drafts.

The heater must not be located immediately below a socket-outlet.

Do not use this radiator in rooms having a surface area less than 45 sq. ft (4 m2).

2. CONNECTION

The radiator must be connected to a properly polarized A/C 110/120 V household outlet in perfect working conditions.

Keep loose clothing or bedding, furniture and flammable material away from the wall outlet where the heater plug is fitted in.

3.GROUND FAULT INTERRUPTION SAFETY DEVICE (GFI PLUG) This device provides protection against electric shock due to ground fault currents by automatically shutting off the power. To test the ope- ration of the GFI plug switch the heater ON at either the 1 or 2 setting. Press the TEST button on the GFI plug device attached to the plug end of the line cord. The heater and fan should stop operating and the Power Light should turn off. Press the RESET button on the GFI plug

device to resume normal operation of the heater. This device should not be used as on ON/OFF operation switch.

“CAUTION: ALTHOUGH THIS DEVICE IS PROVIDED WITH PROTECTION WHICH REDUCES THE RISK OF ELECTRIC SHOCK, THIS PRODUCT SHOULD NEVER BE USED CARELESSLY NEAR WATER.”

4.SWITCHING ON TWO-SWITCH MODELS

Turn thermostat clockwise to the maximum position. Switch on both switches. The lights on the switches remain on independently from of the cycling of the thermostat. When the room reaches the desired temperature, turn the thermostat knob clockwise very slowly and carefully until you hear a “click”. This will automatically set your unit to cycle on and off at that desired heat setting. (For timer instructions, see point 5)

Note: It will normally require approx.15 minutes to reach operating temperature.

3

Image 3
Contents TRN Important Safeguards Location Power EconomizerSwitching on TWO-SWITCH Models Be CarefulAntifreeze function HOW to USE the Timer Please refer to the illustration belowTimer operation USE of ThermostatMaintenance and Service Limited Warranty Instrucciones Importantes Economizador DE Watts UbicaciónConexion Tenga PrecauciónEncendiendo LOS Modelos DE DOS Interruptores USO DEL TermostatoComo Usar EL Roloj DE Tiempo Mantenimiento Y Servicio Funcionamiento del Calentador con el Reloj de TiempoResidentes de los Estados Unidos GarantiaDescripción Y Modelo Horno Tostador Modelo Obtención de servicios de garantíaExclusiones de la garantía Duración de la garantíaPrecauzioni Importanti Sistemazione Dispositivo DI Sicurezza GFI Ground Fault InterruptionAttenzione EconomizzatoreNota Bene USO DEL TimerAccensione NEI Modelli a DUE Interruttori USO DEL TermostatoManutenzione ED Assistenza Garanzia Limitata McLaughlin Road Mississauga, Ontario L5R 4E1 Canada