Honeywell W7752D specifications Excel 10 Wall Module Options

Page 17

EXCEL 10 FCU CONTROLLER LNS PLUG-INS USER GUIDE

Excel 10 Wall Module Options

A typical FCU installation will include an Excel 10 wall module containing a 20k ohm NTC room temperature sensor and additional features depending on the wall module type (see Excel 10 wall module literature for further information).

Excel 10 FCU Controllers can use a return air sensor rather than the sensor in the wall module if it is wired to the wall module sensor input. Setpoint adjustments can be configured as relative or absolute, and upper and lower limits can be set. A configuration option for the fan speed switch allows it to be disabled if not required. The bypass button can be configured to override the control mode to "occupied" for a configurable bypass time and to override the control mode to "unoccupied" for an indefinite time, or it may be configured to only override to "occupied". The button may also be used to cancel the override.

Common Temperature Control (Master/Slave Controllers)

When one or more Excel 10 FCU Controllers serve a common area and a single temperature sensor is to be used, a master/slave arrangement can be configured. One Excel 10 FCU Controller is configured for the local wall module with the desired options. The other Excel 10 FCU Controller(s) will be configured without wall modules and with certain network variables bound with the master controller. Refer to Application Step 6 of this document for more details.

IMPORTANT

The slave units must have the same HVAC equipment connected to it as the master units.

The slave units will not use any internal temperature setpoints or control algorithms. The master controller determines heating/cooling output based upon setpoints and occupancy and LONWORKS network command mode status and communicates this to the slave via the LONWORKS network.

15

EN2B-0285GE51 R0909

Image 17
Contents Excel Appendix C LON Interface Revision History Appendix a Using An LNS tool to Commission a Fan Coil UnitAppendix B Configuring for Master/Slave Operation Typical system overview Description of DevicesOrganization of Manual Products CoveredApplicable Literature Product NamesControl Provided Control ApplicationSetpoint Knob SetpointsSetpoint Limits Setpoint from NetworkZEB Bypass Energy-Saving FeaturesOccupancy Status Operating Modes Safety FeaturesExcel 10 W7752 FCU Controllers ConstructionExcel 10 W7754 FCU Controllers Electrical Shock Hazard180 Controller Performance Specifications Fan Type ConfigurationsGeneral Type of Heating and Cooling Equipment Digital Input Reheat OutputExcel 10 Wall Module Options Common Temperature Control Master/Slave ControllersAbbreviations and Definitions Plan the System OverviewDetermine Other Bus Devices Required Step No DescriptionLonworks Layout Lay Out Communications and Power WiringGeneral Considerations Prepare Wiring DiagramsPower Wiring Power WiringVendor wire type PlenumLOW 230 XAL-Term ONW Orks TerminationExcel 10 Wall Modules Order EquipmentExcel 10 Sensors Echelon-Based Components and PartsUsing Plug-Ins Configure ControllersOutput Input Fan Equipment ControlMiscellaneous Switching LevelsZone Options Troubleshooting Excel 10 FCU Controllers and Wall Modules TroubleshootingAlarms CommissioningReturntonormal FCU AlarmsManual Mode Broadcasting the Service MessageProcedure Temperature Sensor CalibrationInput Configuration Options Output Configuration OptionsZone Control Options Network Variable BindingAppendix C LON Interface Page NV name Continuous Automode To 100% For the reheat output EN2B-0285GE51 R0909 Byte Ntcnonlinearize NoswitchNtcnonlinearized Byte FivepositionDiwindowclosed Byte DinotusedDioccupiedsensor DiairflowOnestage Byte FloatingTwostage ThreestageRelnotused Byte ReheatFreeuse Twopipe FourpipeUword Absolutemiddle OffsetBypassunoccupie NobuttonTable C3. Input Variables for Excel 10 FCU Controllers Modedisable Modeenable UnsuppressalarmsSuppressalarms OcnulInvalid Rqnormal Rqupdatestatus Rqupdatealarm RqreportmaskOFF NUL OFF1OFF2 Byte NormalhcmodeON1OFF2 OFF1ON2Ledoff Ledon Byte NormalfanmodeOpen NowindowClosed Table C4. Output Variables for Excel 10 FCU Controllers Alarmnotifydisabled RtncomfailtempresetRtncomfailsetptoffs RtncomfailschedoccOcbypass Ocstandby Almcomfailmanheat Almcomfailmancool AlmhwswmismatchOFF Notassigned Fieldeffectocc OFF Nofanspeedsw UbyteFieldhwoverride FieldschedoccCtldisabled CtlfanswitchoffOcunoccupied Ocbypass Ocstandby Ocunoccupied Ocbypass Ocstandby OcnulFanoffafteroncmd Not Actice ActiveFanruns ExternalnotacticeInvalid Uword StoffSton Notpressed OFF NoreheatPressed Contactopen Contactclosed UwordInvalid Byte Initial Stlow Stmed SthighDisabled EnabledNoalarm InalarmOpen Nowindow Alarm Suppressalarms AlarmnotifydisabledBugver Nodetype Word Table C5. Unused Variables for Excel 10 FCU ControllersAutomation and Control Solutions

W7752D specifications

The Honeywell W7752D is a versatile and advanced electronic gas combination control designed primarily for use in commercial heating systems. This product stands out for its ability to manage both gas ignition and safety functions, which are critical for maintaining the efficiency and safety of heating appliances. Its robust construction and advanced features make it a popular choice for HVAC professionals and service technicians.

One of the main features of the W7752D is its integration of multiple functions in a single device. It serves as both an automatic gas ignition control and a safety shut-off valve, which simplifies installation and reduces the need for additional components. This integrated design not only enhances reliability but also streamlines maintenance procedures.

Another notable technology utilized in the W7752D is its microprocessor-based control logic. This advanced technology allows for precise management of the ignition sequence, improving the overall efficiency of the heating system. The microprocessor enables the control to adapt to varying operating conditions, ensuring optimal performance even under changing demands.

The W7752D is equipped with features that enhance user-interface and diagnostics capabilities. It includes LED indicators that provide clear information about the operational status and any potential issues. This diagnostics capability facilitates easier troubleshooting, saving time and reducing the likelihood of extended downtimes.

Safety is a primary concern in gas appliances, and the W7752D addresses this with built-in safety mechanisms, including flame detection technologies. These features ensure that the appliance operates safely, automatically shutting down in case of any irregularities during operation. This emphasis on safety not only protects property but also provides peace of mind for users.

In terms of compatibility, the Honeywell W7752D is designed to work with a wide range of gas heating appliances. Its flexibility allows it to be used in various applications, making it suitable for different types of commercial environments. Additionally, the control complies with relevant safety and performance standards, ensuring reliable operation.

In summary, the Honeywell W7752D combines advanced technology with essential safety features, making it a top choice for commercial heating applications. Its integrated design, microprocessor-based control, user-friendly diagnostics, and robust safety mechanisms make it an essential component for efficient and safe gas heating systems. Whether it is for new installations or replacements, the W7752D provides HVAC professionals with the reliability and ease of use they demand.