GE 255 operation manual Display Icons & Cursors, X100

Page 14

Display Icons & Cursors

 

 

16

 

9

10

 

14

 

SU

MO TU

WE

13

 

 

 

a

 

 

 

 

 

Time/Day

 

 

 

 

Regeneration Time

 

 

 

 

15

Salt Amount

 

 

 

 

 

 

 

 

12 13

Capacity

 

P

 

 

 

 

 

26

 

aHardness

 

 

 

 

 

 

 

25

 

 

 

 

 

 

 

23

 

 

 

 

24

 

22

21

 

 

 

 

8 7

FR

20

2

SA DAYS

1

 

 

 

PM

3

 

 

 

 

 

 

4

 

 

 

MIN

 

 

 

 

 

 

g/L

5

a

 

 

 

 

KG

 

 

6

If your Logix 764 controller was

x100

purchased as a filter control, the

17

overlay will show: Time/Day,

Backwash Time, Backwash Length

Lbs/ft3

and Capacity.

 

 

18

19

Note: In normal operation and during programming, only a few of the icons will actually be displayed.

11.The recycle sign is displayed (flashing) when a regeneration at the next time of regeneration has been called for. Also displayed (continuous) when in regeneration.

1.This cursor is displayed when the days between regeneration are being programmed (used with .5 to 99 day regeneration programming).

2.One of these cursors is displayed to indicate which day will be programmed into the controller.

3."PM" indicates that the time displayed is between 12:00 noon and 12:00 midnight (there is no AM indicator). PM indicator is not used if clock mode is set to 24-hour.

4.When "MIN" is displayed, the value entered is in minute increments.

5.When g/L is displayed, the value for regenerant amount entered is in grams/Liter.

6.When "Kg" is displayed, the value entered is in kilograms or kilograins.

7.Four digits used to display the time or program value. Also used for error codes.

8.Colon flashes as part of the time display. Indicates normal operation (742 only).

9.Locked/unlocked indicator. In Level I programming this is displayed when the current parameter is locked-out. It is also used in Level II programming to indicate if the displayed parameter is locked (icon flashes) when controller is in Level I.

10.When "x2" is displayed, a second regeneration has been called for.

12.The display cursor is next to "SALT AMOUNT" when programming the amount of regenerant. If the controller is on a 3-cycle filter then backwash time is programmed.

13.The display cursor is next to "REGENERATION TIME" when programming the time of regeneration and the days of regeneration.

14.The display cursor is next to "TIME/DAY" when programming the current time and day.

15.The hourglass is displayed when the motor is running. The camshaft should be turning.

16.These cursors appear next to the item that is currently displayed.

17.X100 multiplier for large values.

18.When Lbs/ft3 is displayed the value for regenerant amount entered is in pounds/cubic foot.

19.Faucet is displayed when the current flow rate is displayed. Control may show the faucet and "0", indicating no flow.

20.Maintenance interval display turns on if the months in service exceed the value programmed in P11.

21.Used with #24, #25, and #26. Displays valve in service, a sequence number or a value.

22.History Values (H). The number displayed by #23 identifies which history value is currently displayed.

14

Image 14
Contents Models LockoutPage Table of Contents Safety Information Back How To Use This ManualFront Location Selection Outdoor LocationsUnconditioned water Conditioned water out Water Line Connection InstallationLocation Selection Brine Tank Overflow Line Connection Drain Line ConnectionBrine Line Connection VAC AC Adapters Electrical ConnectionBrine Tank Disinfection of Water Conditioning Systems System Operation Valve Disc Location/Function Power Loss Memory RetentionCamshaft Cycle Positions Control OperationDisplay Icons & Cursors X100Keypad Buttons Programming ConventionsRemove air from tanks Power-up the ControlPlacing Water Conditioning System Into Operation Preprogrammed Valves TypeResin Volume 0.25 ft3 and 5 Liter Steps MetricScreen Buttons to Description Quick Cycling the Control 255L and 255P To Place the 255 Alternating System into Operation Fully OperationalQuick Cycling the Control for 255A Systems C8 Regenerant Refill Quick cycle to Service Level I Programming Service DisplayProgramming Overview Logix 764 Electronic Multi-Tank a Alternating ControlDescription Range Minimum Default Units Level II Programming P ValuesSalt Setting Programming the Lockout FeatureSalt Setting Exchange Capacity 255 ValveDescription Range Minimum Default Level lll Cycle Programming C ValuesHistory Data Description Range Program ResetLevel IV Viewing History H Values Manual Regeneration Options Delayed Manual RegenerationDelayed Second Regeneration Immediate Manual RegenerationHigh Ave Low P16 = Regeneration Modes for Parallel SystemsP16 = Priority Flow Continuous Efficiency High Ave LowWiring Diagrams Remote Regeneration StartConnecting the Logix 764 Multi Single Tank Control Parts Lists Exploded View & Parts ListDescription Qty NumberTurbine Adapter Part Description Qty Bypass Valve and Turbine AdapterBypass Manifold Kits Troubleshooting Controller Error Codes & 255 L with Check Salt LightSystem Troubleshooting Problem Possible Cause SolutionReset control and program resin volume Page Page Copyright 2007 General Electric Company P/N 3019624 Rev a

255 specifications

The GE 255 is a versatile and powerful gas turbine, known for its exceptional efficiency and reliability in various industrial applications. As one of the flagship models from General Electric, the GE 255 has garnered attention for its performance, design, and technological advancements.

One of the main features of the GE 255 is its advanced aerodynamics. The turbine incorporates cutting-edge blade designs that enhance airflow and optimize combustion efficiency. These aerodynamic improvements contribute to increased power output, allowing the turbine to generate more energy while consuming less fuel. The efficiency of the GE 255 makes it an attractive option for power plants looking to reduce operational costs while maintaining high output levels.

In addition to its aerodynamic features, the GE 255 is equipped with sophisticated combustion technology. This technology enables the turbine to achieve low emissions, adhering to strict environmental regulations. The combustion system is designed to provide stable and reliable operation across various load conditions, ensuring that power generation remains consistent even in fluctuating demand scenarios.

The GE 255 also boasts a modular design, allowing for easier maintenance and upgrades. The components are designed with serviceability in mind, ensuring that downtime is minimized during routine inspections or repairs. This modular approach not only enhances the overall lifespan of the turbine but also allows operators to implement technology upgrades as they become available, ensuring that the equipment remains state-of-the-art.

Moreover, the GE 255 integrates advanced monitoring and control systems that provide real-time data on performance and operational health. These systems enable operators to make informed decisions, optimizing performance and identifying potential issues before they escalate. The data collected can be analyzed to improve operational practices and reduce maintenance costs.

The turbine's robust construction also contributes to its reliability. Built to withstand harsh operating conditions, the GE 255 includes features that protect critical components from wear and degradation. This durability extends the operational life of the turbine and enhances its overall availability for power generation.

In summary, the GE 255 is a state-of-the-art gas turbine distinguished by its advanced aerodynamics, low emissions combustion technology, modular design, and robust monitoring systems. It represents a blend of efficiency and reliability, making it a leading choice for energy providers aiming to maximize output while minimizing environmental impact. Its combination of innovative features positions the GE 255 as a significant player in the competitive landscape of gas turbines.