Level lll Cycle Programming – C Values
Several Level III program parameters can be adjusted to
accessible by pressing and holding the UP and SET buttons until the display shows a “C” value.
Note: The control must by in the treated water position to change settings.
C# | Description | Range | Minimum | Default | Notes | |
Increments | Setting | |||||
|
|
|
| |||
|
|
|
|
|
| |
C1 | Backwash | 0 – 200 | 1 Min | 14 | Flow rate dictated by size of drain line flow | |
controller | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
C2 | Regenerant Draw | Not | 1 Min | See Notes | Automatically calculated from resin volume | |
Adjustable | and salt dosage settings | |||||
|
|
|
|
|
| |
C3 | Slow Rinse | 0 – 200 | 1 Min | See Notes | Automatically calculated from resin volume | |
and salt dosage settings | ||||||
|
|
|
|
|
| |
C4 | Repressurization | 0 – 200 | 1 Min | 3 | Allows system to equalize water pressure | |
across valve discs | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
C5 | Fast Rinse | 0 – 200 | 1 Min | 6 | Rinses residual regenerant from tank | |
|
|
|
|
|
| |
C6 | 2nd Backwash | 0 – 200 | 1 Min | 1 | Disperses non regenerated areas of the | |
resin bed | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
C7 | 2nd Fast Rinse | 0 – 200 | 1 Min | 1 | Rinses to Quality | |
|
|
|
|
|
| |
C8 | Regenerant Refill | Not | 1 Min | See Notes | Automatically calculated from resin volume | |
Adjustable | and salt dosage settings | |||||
|
|
|
|
|
|
25