GE 255 operation manual Reset control and program resin volume

Page 37

Hard water leakage after

a.

Improper regeneration.

a.

Repeat regeneration after making

regeneration.

 

 

 

certain correct regenerant dosage was

 

 

 

 

set.

 

b.

Leaking of external bypass valve.

b.

Replace bypass valve. (Contact dealer).

 

c.

O-Ring around riser pipe damaged.

c.

Replace O-ring

 

d.

System capacity too low due to

d.

Reset control and program resin volume

 

 

incorrect resin volume setting

 

to correct setting

 

 

 

 

 

Control will not draw

a.

Low water pressure.

a.

Make correct setting according to

regenerant.

 

 

 

instructions.

 

b.

Restricted drain line.

b.

Remove restriction.

 

c.

Injector plugged.

c.

Clean injector and screen.

 

d.

Injector defective.

d.

Replace injector and cap. (Contact

 

 

 

 

dealer).

 

e.

Valve disc 2 and/or 3 not closed.

e.

Remove foreign matter from disc and

 

 

 

 

check disc for closing by pushing in on

 

 

 

 

stem. Replace if needed. (Contact

 

 

 

 

dealer).

 

f.

Air check valve prematurely closed.

f.

Put control momentarily into brine refill.

 

 

 

 

Replace or repair air check if needed.

 

 

 

 

(Contact dealer).

 

 

 

 

 

Control will not regenerate

a.

AC adapter or motor not connected.

a.

Connect power.

automatically.

b.

Defective motor.

b.

Replace motor. (Contact dealer).

 

c.

Fouled or defective turbine.

c.

Clean or replace turbine assembly.

 

d.

Defective turbine cable.

d.

Replace turbine cable.

 

 

 

 

 

Control regenerates at wrong

a.

Controller set incorrectly.

a.

Correct the time setting according to

time of day.

 

 

 

instructions.

 

 

 

 

 

Intermittent or irregular

a.

Low water pressure.

a.

Set pump to maintain 20 psi at

regenerant draw.

b.

Defective injector.

 

conditioner.

 

b.

Replace injector (Contact dealer).

 

 

 

 

 

 

 

 

No conditioned water after

a.

No regenerant in regenerant tank.

a.

Add regenerant to regenerant tank.

regeneration.

b.

Injector plugged.

b.

Clean injector and screen.

 

 

c.

Air check valve closes prematurely.

c.

Quick cycle control into regenerant

 

 

 

 

draw/slow rinse. Replace or repair air

 

 

 

 

check if needed. (Contact dealer).

 

 

 

 

 

Backwashes or purges at

a.

Incorrect drain controller used.

a.

Replace with correct size controller

excessively low or high rate.

 

 

 

(Contact dealer).

 

b.

Foreign matter affecting valve

b.

Remove drain controller and clean ball

 

 

operation.

 

and seat.

 

 

 

 

 

Run out of conditioned water

a.

Improper regeneration.

a.

Repeat regeneration,

between regenerations.

b.

Incorrect resin volume setting

b.

Reset control and program resin volume

 

 

 

 

 

to correct setting

 

 

 

 

 

Control displays 1 - x (1 thru

a.

Control is in test mode

a.

Press control keys in order from left to

4)

 

 

 

right.

 

 

 

 

 

37

Image 37
Contents Lockout ModelsPage Table of Contents Safety Information Front How To Use This ManualBack Outdoor Locations Location SelectionUnconditioned water Conditioned water out Location Selection InstallationWater Line Connection Brine Line Connection Drain Line ConnectionBrine Tank Overflow Line Connection Brine Tank Electrical ConnectionVAC AC Adapters Disinfection of Water Conditioning Systems System Operation Camshaft Cycle Positions Power Loss Memory RetentionValve Disc Location/Function Control OperationX100 Display Icons & CursorsProgramming Conventions Keypad ButtonsPlacing Water Conditioning System Into Operation Power-up the ControlRemove air from tanks Preprogrammed Valves TypeMetric Resin Volume 0.25 ft3 and 5 Liter StepsScreen Buttons to Description Quick Cycling the Control 255L and 255P Quick Cycling the Control for 255A Systems Fully OperationalTo Place the 255 Alternating System into Operation C8 Regenerant Refill Quick cycle to Service Programming Overview Service DisplayLevel I Programming Logix 764 Electronic Multi-Tank a Alternating ControlLevel II Programming P Values Description Range Minimum Default UnitsSalt Setting Programming the Lockout FeatureSalt Setting Exchange Capacity 255 ValveLevel lll Cycle Programming C Values Description Range Minimum DefaultLevel IV Viewing History H Values Program ResetHistory Data Description Range Delayed Second Regeneration Delayed Manual RegenerationManual Regeneration Options Immediate Manual RegenerationP16 = Priority Flow Continuous Efficiency Regeneration Modes for Parallel SystemsHigh Ave Low P16 = High Ave LowRemote Regeneration Start Wiring DiagramsConnecting the Logix 764 Multi Single Tank Control Exploded View & Parts List Parts ListsNumber Description QtyBypass Bypass Valve and Turbine AdapterTurbine Adapter Part Description Qty Manifold Kits Controller Error Codes & 255 L with Check Salt Light TroubleshootingProblem Possible Cause Solution System TroubleshootingReset control and program resin volume Page Page Copyright 2007 General Electric Company P/N 3019624 Rev a