GE 255 operation manual Description Qty, Number

Page 32

Item

Part

Description

Qty.

Item

Part

Description

Qty.

Number

No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

3014650

764 Series Control

1

17

1000269

Injector Cap with O-Ring

1

2

1244650

Valve Assembly w/o Flow Controls

1

18

1243511

0.33 Refill Ball & Cone Type Flow Controller

1

3

1235340

Top Plate

1

19

 

Air Check Kit

1

4

1234170

Screw, Top Plate

12

 

1032416

3/8 –inch male

 

5

1235341

Valve Disc Spring, 255 Valve

1

 

1032417

1/4-inch NPT male threads

 

6

1236251

Cam 255 Logix Valve, Twin Tan

1

20

1033784

Tank Adapter

1

7

1236246

Cover, Grey

1

21

1010429

O-Ring, Tank

1

8

1000811

AC Adapter, North American

1

22

1232370

O-Ring, Riser

1

9

3019221

Motor/Optical Cable

1

23

1001404

O-Ring Group, Tank Adapter

 

10

1000226

Screen/Cap Assembly w/O-Ring

1

24

3016715

Assy, Sensor Cable Logix Twin

1

11

1031402

Locking Bar, English

 

25

3016775

Assy, Cable Extension 3 m (9.8 ft), Logix Twin

1

12

1006093

Screw, Locking Bar

 

26

3020228

Assy, Cable Remote Start/Multi-Tank

 

13

 

Drain Control Assembly:

1

 

 

Lockout, 3 m (9.8 ft)

1

 

1000208

No. 6 (10 gpm; 3.8 Lpm)

 

27

1254886

Secondary Faceplate (blank)

1

 

1000209

No. 7 (1.3 gpm; 4.9 Lpm)

 

28

1032347

Assy, Adapter 1-inch Turbine

1

 

1000210

No. 8 (1.6 gpm; 6 Lpm)

 

*

1000250

Valve Disc Kit

1

 

1000211

No. 9 (2 gpm; 7.6 Lpm)

 

*

1040769

256 Bypass Valve Kit (Optional)

1

 

1000212

No. 10 (2.5 gpm; 9.5 Lpm)

 

*

1267808

Valve Skirt

1

 

1000213

No. 12 (3.9 gpm; 14.8 Lpm)

 

29

1235446

Turbine Cable

1

 

1000214

No. 13 (4.5 gpm; 17 Lpm)

 

 

 

 

 

 

1000215

No. 14 (5.3 gpm; 20 Lpm)

 

 

 

 

 

14

1030502

Ball, Flow Restrictor

1

 

 

 

 

15

1040459

O-ring Group, Piping Boss

 

 

 

 

 

16

 

Injector Options:

1

 

 

 

 

 

1035730

“E” Injector, Yellow, 6-inch tank

 

 

 

 

 

 

1035731

“F” Injector, Peach, 7-inch tank

 

 

 

 

 

 

1035732

“G” Injector, Tan, 8-inch tank

 

 

 

 

 

 

1035733

“H” Injector, Lt Purple 9-inch tank

 

 

 

 

 

 

1035734

“J” Injector, Lt Blue 10-inch tank

 

 

 

 

 

 

1035735

“K” Injector, Pink 12-inch tank

 

 

 

 

 

 

1035736

“L” Injector, Orange, 13 & 14-inch tank

 

 

 

 

 

 

 

 

 

 

 

 

 

* Not Shown on Drawing

32

Image 32
Contents Models LockoutPage Table of Contents Safety Information Back How To Use This ManualFront Location Selection Outdoor LocationsUnconditioned water Conditioned water out Water Line Connection InstallationLocation Selection Brine Tank Overflow Line Connection Drain Line ConnectionBrine Line Connection VAC AC Adapters Electrical ConnectionBrine Tank Disinfection of Water Conditioning Systems System Operation Power Loss Memory Retention Camshaft Cycle PositionsValve Disc Location/Function Control OperationDisplay Icons & Cursors X100Keypad Buttons Programming ConventionsPower-up the Control Placing Water Conditioning System Into OperationRemove air from tanks Preprogrammed Valves TypeResin Volume 0.25 ft3 and 5 Liter Steps MetricScreen Buttons to Description Quick Cycling the Control 255L and 255P To Place the 255 Alternating System into Operation Fully OperationalQuick Cycling the Control for 255A Systems C8 Regenerant Refill Quick cycle to Service Service Display Programming OverviewLevel I Programming Logix 764 Electronic Multi-Tank a Alternating ControlDescription Range Minimum Default Units Level II Programming P ValuesProgramming the Lockout Feature Salt SettingSalt Setting Exchange Capacity 255 ValveDescription Range Minimum Default Level lll Cycle Programming C ValuesHistory Data Description Range Program ResetLevel IV Viewing History H Values Delayed Manual Regeneration Delayed Second RegenerationManual Regeneration Options Immediate Manual RegenerationRegeneration Modes for Parallel Systems P16 = Priority Flow Continuous EfficiencyHigh Ave Low P16 = High Ave LowWiring Diagrams Remote Regeneration StartConnecting the Logix 764 Multi Single Tank Control Parts Lists Exploded View & Parts ListDescription Qty NumberTurbine Adapter Part Description Qty Bypass Valve and Turbine AdapterBypass Manifold Kits Troubleshooting Controller Error Codes & 255 L with Check Salt LightSystem Troubleshooting Problem Possible Cause SolutionReset control and program resin volume Page Page Copyright 2007 General Electric Company P/N 3019624 Rev a

255 specifications

The GE 255 is a versatile and powerful gas turbine, known for its exceptional efficiency and reliability in various industrial applications. As one of the flagship models from General Electric, the GE 255 has garnered attention for its performance, design, and technological advancements.

One of the main features of the GE 255 is its advanced aerodynamics. The turbine incorporates cutting-edge blade designs that enhance airflow and optimize combustion efficiency. These aerodynamic improvements contribute to increased power output, allowing the turbine to generate more energy while consuming less fuel. The efficiency of the GE 255 makes it an attractive option for power plants looking to reduce operational costs while maintaining high output levels.

In addition to its aerodynamic features, the GE 255 is equipped with sophisticated combustion technology. This technology enables the turbine to achieve low emissions, adhering to strict environmental regulations. The combustion system is designed to provide stable and reliable operation across various load conditions, ensuring that power generation remains consistent even in fluctuating demand scenarios.

The GE 255 also boasts a modular design, allowing for easier maintenance and upgrades. The components are designed with serviceability in mind, ensuring that downtime is minimized during routine inspections or repairs. This modular approach not only enhances the overall lifespan of the turbine but also allows operators to implement technology upgrades as they become available, ensuring that the equipment remains state-of-the-art.

Moreover, the GE 255 integrates advanced monitoring and control systems that provide real-time data on performance and operational health. These systems enable operators to make informed decisions, optimizing performance and identifying potential issues before they escalate. The data collected can be analyzed to improve operational practices and reduce maintenance costs.

The turbine's robust construction also contributes to its reliability. Built to withstand harsh operating conditions, the GE 255 includes features that protect critical components from wear and degradation. This durability extends the operational life of the turbine and enhances its overall availability for power generation.

In summary, the GE 255 is a state-of-the-art gas turbine distinguished by its advanced aerodynamics, low emissions combustion technology, modular design, and robust monitoring systems. It represents a blend of efficiency and reliability, making it a leading choice for energy providers aiming to maximize output while minimizing environmental impact. Its combination of innovative features positions the GE 255 as a significant player in the competitive landscape of gas turbines.