POWER VENTING

Heaters may be connected to systems requiring mechanical draft exhaust fans. The installation must be engineered by competent personnel in accordance with the latest edition of ANSI Z 223.1, local codes and with the supplier of the fan.

Particular attention must be given to the type of vent pipe used, its size and location. Suitable interlocks must be provided to prevent heater operation until the fan is operating as designed.

OUTDOORWATERHEATERS

The point from where the flue products exit the heater must be a minimum of four (4) feet below, four (4) feet horizontally from or one (1) foot above any door, window or gravity inlet to a building. The top surface of the heater shall be at least three (3) feet above any forced air inlet, or intake ducts located within ten (10) feet horizontally.

Fig. #8245.1

HIGH WIND CONDITIONS (Outdoor Units Only)

In areas where high winds are frequent, it may be necessary to locate the heater a minimum of 3' from high vertical walls, or install a wind break so the heater is not in direct wind current.

VENT DAMPER INSTALLATION

(MODELS 136 THROUGH 264) WHERE REQUIRED

LOCATION

The vent damper must be located in the vent so that it serves only the appliance for which it is intended.

If improperly installed, a hazardous condition, such as an explosion or carbon monoxide poisoning, could result. Make certain that it is mounted in an accessible location at least 6 in. (152.4 mm) from any combustible material or the heat exchanger and that the position indicator is in a visible location.

Theventdampermustbeinstalledaftertheappliance draft hood, as close to the draft hood as practicable, and without modification of the draft hood.

Fig. # 8182.0

16

Image 16
Contents Important Warning Catalog NO. RM-001Electric Code ANSI/NFPA Index Construction Features Series GB For circulating tank systems Through 1826 MbtuhSpecification Data Page Shipping Installation Regulations ReceivingequipmentWater Flow Water ConditionsCombustible Floor Base BaserequirementsBoiler Part Combustibleconstructionclearances Protected SurfacesCombustion and Ventilation AIR Supply Recommended Minimum AIR OpeningsMODEL181-399 ModelMODELS926-1758 Models 512Indoorheaters Models Heater Before Heater After Drafthood Installation MODELS181-399Page Fig. #7043.1 Power Venting Vent Damper InstallationModels 136 Through 264 Where Required Location OutdoorwaterheatersMounting Normal Operation SummaryGas Natural Propane BTU/CFSP. GR Pipe SizesTest piping as follows Fig.#8185.1Cold Water Supply WaterGPM NPT HOT Water Supply Heater TanktemperaturecontrolSeries with 115 Volt Supply to the Heater Piping DIAGRAM-1 Heater 1 Tank Thermostat Supplied Installation Water Heater PlumbingSequenceofoperation Piping DIAGRAM-1 Heater 2 Tank Piping Must be Equal Between Tees and TANKS. NotesPiping DIAGRAM-1 Heater 3 Tank Fig. # 8067-RHEEMPiping DIAGRAM-1 Heater 4 Tank Piping DIAGRAM-2 Heater 1 Tank Special Thermostat and Well Energy Saving Pump Control Description of Controls in GeneralElectronicignition Flow Switch Tankstat Temperature ControlHighlimit Electrical Single Stage TankstatSTART-UP ON-OFFOPERATIONTIME/TEMPERATURE Relationships in Scalds ScaldingFor Your Safety Read Before Operating Close all manual gas valves. Turn off electric power To Shut DownMonthly Inspectionand MaintenanceproceduresSix Months System Shut Down Procedure Service AssistanceBurner Inspection Venting System InspectionTrouble Shooting Problem If okay replace ignition module Electrical Electronic Ignition IID Models 512 StartWiring Diagram KEY Wiring Diagrams Wiring Diagram Models 331 Wiring Diagram Models 512Wiring Diagram Models Wiring Diagram Models 726Wiring Diagram Model 825 Wiring Diagram Models 962 Fig. # 1967eReplacement Parts Lists Model 136 GB onlyModel 136 GB only Models 181, 264, 331, 399 GB Page Models 181, 264, 331, 399 GB Models 181, 264, 331,339 GB Models 512, 627, 726, 825 GB Models 512, 627, 726, 825 GB Models 512, 627, 726, 825 GB Models 926-1826 GB Models 926-1826 GB Models 926-1826 GB

136-1826 specifications

The Rheem 136-1826 is a highly efficient heating and cooling unit designed to provide reliable performance and comfort in residential settings. This unit is particularly notable for its advanced features, robust technologies, and outstanding characteristics that set it apart in the HVAC market.

One of the defining features of the Rheem 136-1826 is its energy efficiency. Rated with a high Seasonal Energy Efficiency Ratio (SEER), this unit efficiently converts energy into cooling output, leading to significant savings on utility bills. The environmentally friendly refrigerants used in its operation comply with current global regulations and aim to minimize any negative impact on the ozone layer.

Additionally, the Rheem 136-1826 incorporates advanced climate control technologies. Its innovative multi-stage compression offers superior cooling performance and an enhanced ability to maintain comfortable temperatures, even during extreme weather conditions. The variable-speed motor allows for precise airflow management, leading to quieter operation and improved indoor air quality by minimizing dust and allergens in circulation.

Another remarkable attribute of the Rheem 136-1826 is its smart technology integration. Homeowners can connect the unit to Wi-Fi and control it remotely through a mobile app. This feature not only provides convenience but also allows users to monitor system performance, adjust settings, and receive maintenance reminders. The programmable thermostat included in the setup further enhances energy conservation efforts, enabling users to tailor their heating and cooling schedules to their lifestyle.

In terms of installation and maintenance, the Rheem 136-1826 has been designed with user-friendliness in mind. Its compact size allows for easy installation in various locations, making it a versatile choice for different home designs. The durable construction materials used in this unit ensure longevity and reduced maintenance needs over time.

Overall, the Rheem 136-1826 stands out for its combination of energy efficiency, advanced cooling technologies, smart features, and ease of use. It is an ideal choice for homeowners looking for a reliable and efficient heating and cooling solution that not only enhances indoor comfort but also contributes to long-term energy savings. Whether replacing an old system or installing a new one, the Rheem 136-1826 is well-equipped to meet the demands of modern living.