Rheem 136-1826 installation instructions Problem

Page 36

Problem

1.Heater will not operate:

TROUBLE SHOOTING

Possible Cause

Electrical:

Main power

Manual reset switch.

Operating controller.

Controller in-operative.

Flow Switch Mechanical:

Gas Line

Plugged bleedline on pressure regulator, gas valves, etc.

Broken pump coupler.

Action

Check circuit breaker, fuses, etc. Power at boiler control switch should be 115 volts.

Check all controls. If reset is tripped determine reason and correct. Check power to all controls with voltmeter. Adjust to desired operat- ing temperatures.

Remove sensor. Check for immer- sion or sensing.

Replace if faulty.

Check pump for operation.

Open shutoff cock(s)

Loosen bleed line and clean.

Check reason for failure.

Inspect bearing assembly, shaft and impeller.

Replace coupling.

Gas valve will not open:

1.Diaphram type.

2.Motorized type

Check bleed line. Clean. Check solenoid. Replace if defective.

Check auxiliary switches.

a.Auxiliary switch;

b.Valve closed switch.

Power should be 115 volts.

2.Pilot burner will not light

Note: Actuator is not field repairable. If problem is other than switch(es) replace.

3. Combination type

Check

controller.

Intermittent Ignition Module

Check

power to 25 VAC input

(IID)

terminal

 

1. If 25 VAC:

- Check for 1/8" spark @ pilot. a. Spark ok:

• Check gas supply.

• Burner orifice.

• Dampness @ electrode or high tension wire.

• Check for 25 VAC @ PV; MV/PV terminals. 1. Voltage @ 25 VAC

- Replace pilot valve. 2. Voltage not @ 25 VAC

- Replace module. 2. No 25 VAC @ input terminal.

- Check transformer output. a. 25 VAC

• Check limit circuit. b. No 25 VAC

• Replace transformer.

36

Image 36
Contents Catalog NO. RM-001 Important WarningElectric Code ANSI/NFPA Index Construction Features Series GB For circulating tank systems Through 1826 MbtuhSpecification Data Page Shipping Installation Regulations ReceivingequipmentWater Flow Water ConditionsBaserequirements Combustible Floor BaseBoiler Part Combustibleconstructionclearances Protected SurfacesCombustion and Ventilation AIR Supply Recommended Minimum AIR OpeningsMODEL181-399 ModelModels 512 MODELS926-1758Indoorheaters Models Heater Before Heater After Drafthood Installation MODELS181-399Page Fig. #7043.1 Power Venting Vent Damper InstallationModels 136 Through 264 Where Required Location OutdoorwaterheatersMounting Normal Operation SummaryGas Natural Propane BTU/CFSP. GR Pipe SizesTest piping as follows Fig.#8185.1Water Cold Water SupplyGPM NPT Tanktemperaturecontrol HOT Water Supply HeaterSeries with 115 Volt Supply to the Heater Installation Water Heater Plumbing Piping DIAGRAM-1 Heater 1 Tank Thermostat SuppliedSequenceofoperation Piping DIAGRAM-1 Heater 2 Tank Piping Must be Equal Between Tees and TANKS. NotesPiping DIAGRAM-1 Heater 3 Tank Fig. # 8067-RHEEMPiping DIAGRAM-1 Heater 4 Tank Piping DIAGRAM-2 Heater 1 Tank Special Thermostat and Well Description of Controls in General Energy Saving Pump ControlElectronicignition Tankstat Temperature Control Flow SwitchHighlimit Electrical Single Stage TankstatSTART-UP ON-OFFOPERATIONTIME/TEMPERATURE Relationships in Scalds ScaldingFor Your Safety Read Before Operating Close all manual gas valves. Turn off electric power To Shut DownInspectionand Maintenanceprocedures MonthlySix Months System Shut Down Procedure Service AssistanceBurner Inspection Venting System InspectionTrouble Shooting Problem If okay replace ignition module Electrical Electronic Ignition IID Models 512 StartWiring Diagram KEY Wiring Diagrams Wiring Diagram Models 331 Wiring Diagram Models 512Wiring Diagram Models Wiring Diagram Models 726Wiring Diagram Model 825 Wiring Diagram Models 962 Fig. # 1967eReplacement Parts Lists Model 136 GB onlyModel 136 GB only Models 181, 264, 331, 399 GB Page Models 181, 264, 331, 399 GB Models 181, 264, 331,339 GB Models 512, 627, 726, 825 GB Models 512, 627, 726, 825 GB Models 512, 627, 726, 825 GB Models 926-1826 GB Models 926-1826 GB Models 926-1826 GB

136-1826 specifications

The Rheem 136-1826 is a highly efficient heating and cooling unit designed to provide reliable performance and comfort in residential settings. This unit is particularly notable for its advanced features, robust technologies, and outstanding characteristics that set it apart in the HVAC market.

One of the defining features of the Rheem 136-1826 is its energy efficiency. Rated with a high Seasonal Energy Efficiency Ratio (SEER), this unit efficiently converts energy into cooling output, leading to significant savings on utility bills. The environmentally friendly refrigerants used in its operation comply with current global regulations and aim to minimize any negative impact on the ozone layer.

Additionally, the Rheem 136-1826 incorporates advanced climate control technologies. Its innovative multi-stage compression offers superior cooling performance and an enhanced ability to maintain comfortable temperatures, even during extreme weather conditions. The variable-speed motor allows for precise airflow management, leading to quieter operation and improved indoor air quality by minimizing dust and allergens in circulation.

Another remarkable attribute of the Rheem 136-1826 is its smart technology integration. Homeowners can connect the unit to Wi-Fi and control it remotely through a mobile app. This feature not only provides convenience but also allows users to monitor system performance, adjust settings, and receive maintenance reminders. The programmable thermostat included in the setup further enhances energy conservation efforts, enabling users to tailor their heating and cooling schedules to their lifestyle.

In terms of installation and maintenance, the Rheem 136-1826 has been designed with user-friendliness in mind. Its compact size allows for easy installation in various locations, making it a versatile choice for different home designs. The durable construction materials used in this unit ensure longevity and reduced maintenance needs over time.

Overall, the Rheem 136-1826 stands out for its combination of energy efficiency, advanced cooling technologies, smart features, and ease of use. It is an ideal choice for homeowners looking for a reliable and efficient heating and cooling solution that not only enhances indoor comfort but also contributes to long-term energy savings. Whether replacing an old system or installing a new one, the Rheem 136-1826 is well-equipped to meet the demands of modern living.