Rheem 136-1826 installation instructions HOT Water Supply Heater, Tanktemperaturecontrol

Page 21

HOT WATER SUPPLY HEATER

Model 136- 1826

The heater is direct fired and used with a storage tank. The model number indicates the BTU/holds input. (i.e. an 1826 holds input of 1,826,000 BTU/ HR)

See specification and dimension information on pages 4, 5 and 6.

TANKTEMPERATURECONTROL

1.The tank temperature controller is shipped loose for installation in the field. It is found in the burner tray.

2.Install in the tapping provided in the storage tank as shown.

3.Wire the "TH" leads, provided in the boiler control box, to the tank temperature controller. DO NOT WIRE IN

SERIES WITH 115 VOLT SUPPLY TO THE HEATER.

NOTE: The "TH" wires are in the 24 volt control circuit. DO NOT connect to the 115 volt circuit.

4.Set temperature to 140°F or to desired tank temperature.

21

Image 21
Contents Catalog NO. RM-001 Important WarningElectric Code ANSI/NFPA Index Series GB For circulating tank systems Through 1826 Mbtuh Construction FeaturesSpecification Data Page Shipping Receivingequipment Installation RegulationsWater Flow Water ConditionsBaserequirements Combustible Floor BaseBoiler Part Protected Surfaces CombustibleconstructionclearancesRecommended Minimum AIR Openings Combustion and Ventilation AIR SupplyMODEL181-399 ModelModels 512 MODELS926-1758Indoorheaters Models MODELS181-399 Heater Before Heater After Drafthood InstallationPage Fig. #7043.1 Vent Damper Installation Power VentingModels 136 Through 264 Where Required Location OutdoorwaterheatersNormal Operation Summary MountingBTU/CF Gas Natural PropaneSP. GR Pipe SizesFig.#8185.1 Test piping as followsWater Cold Water SupplyGPM NPT Tanktemperaturecontrol HOT Water Supply HeaterSeries with 115 Volt Supply to the Heater Installation Water Heater Plumbing Piping DIAGRAM-1 Heater 1 Tank Thermostat SuppliedSequenceofoperation Piping Must be Equal Between Tees and TANKS. Notes Piping DIAGRAM-1 Heater 2 TankFig. # 8067-RHEEM Piping DIAGRAM-1 Heater 3 TankPiping DIAGRAM-1 Heater 4 Tank Piping DIAGRAM-2 Heater 1 Tank Special Thermostat and Well Description of Controls in General Energy Saving Pump ControlElectronicignition Tankstat Temperature Control Flow SwitchHighlimit Single Stage Tankstat ElectricalSTART-UP ON-OFFOPERATIONScalding TIME/TEMPERATURE Relationships in ScaldsFor Your Safety Read Before Operating To Shut Down Close all manual gas valves. Turn off electric powerInspectionand Maintenanceprocedures MonthlySix Months Service Assistance System Shut Down ProcedureBurner Inspection Venting System InspectionTrouble Shooting Problem If okay replace ignition module Start Electrical Electronic Ignition IID Models 512Wiring Diagram KEY Wiring Diagrams Wiring Diagram Models 512 Wiring Diagram Models 331Wiring Diagram Models 726 Wiring Diagram ModelsFig. # 1967e Wiring Diagram Model 825 Wiring Diagram Models 962Model 136 GB only Replacement Parts ListsModel 136 GB only Models 181, 264, 331, 399 GB Page Models 181, 264, 331, 399 GB Models 181, 264, 331,339 GB Models 512, 627, 726, 825 GB Models 512, 627, 726, 825 GB Models 512, 627, 726, 825 GB Models 926-1826 GB Models 926-1826 GB Models 926-1826 GB

136-1826 specifications

The Rheem 136-1826 is a highly efficient heating and cooling unit designed to provide reliable performance and comfort in residential settings. This unit is particularly notable for its advanced features, robust technologies, and outstanding characteristics that set it apart in the HVAC market.

One of the defining features of the Rheem 136-1826 is its energy efficiency. Rated with a high Seasonal Energy Efficiency Ratio (SEER), this unit efficiently converts energy into cooling output, leading to significant savings on utility bills. The environmentally friendly refrigerants used in its operation comply with current global regulations and aim to minimize any negative impact on the ozone layer.

Additionally, the Rheem 136-1826 incorporates advanced climate control technologies. Its innovative multi-stage compression offers superior cooling performance and an enhanced ability to maintain comfortable temperatures, even during extreme weather conditions. The variable-speed motor allows for precise airflow management, leading to quieter operation and improved indoor air quality by minimizing dust and allergens in circulation.

Another remarkable attribute of the Rheem 136-1826 is its smart technology integration. Homeowners can connect the unit to Wi-Fi and control it remotely through a mobile app. This feature not only provides convenience but also allows users to monitor system performance, adjust settings, and receive maintenance reminders. The programmable thermostat included in the setup further enhances energy conservation efforts, enabling users to tailor their heating and cooling schedules to their lifestyle.

In terms of installation and maintenance, the Rheem 136-1826 has been designed with user-friendliness in mind. Its compact size allows for easy installation in various locations, making it a versatile choice for different home designs. The durable construction materials used in this unit ensure longevity and reduced maintenance needs over time.

Overall, the Rheem 136-1826 stands out for its combination of energy efficiency, advanced cooling technologies, smart features, and ease of use. It is an ideal choice for homeowners looking for a reliable and efficient heating and cooling solution that not only enhances indoor comfort but also contributes to long-term energy savings. Whether replacing an old system or installing a new one, the Rheem 136-1826 is well-equipped to meet the demands of modern living.