Desa installation manual Local Codes, Unpacking, Product Features, AIR for Combustion Ventilation

Page 5

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the lat- est edition of The National Fuel Gas Code ANSI

Z223/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are required, thermostat models are not permitted.

State of Massachusetts: The installa- tion must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

Vent-free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts.

UNPACKING

CAUTION: Do not remove the data plates from the grate as- sembly. The data plates contain important warranty and safety information.

1.Remove logs and heater base assembly from carton. Note: Do not pick up heater base as- sembly by burners. This could damage heater. Always handle base assembly by grate.

2.Remove all protective packaging applied to logs and heater for shipment.

3.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.

PRODUCT FEATURES

OPERATION

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic, dancing yellow flames. This heater is designed for vent-free operation with flue damper closed. It has been tested and approved to ANSI Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of vent-free heaters. Non-thermostat models may also be operated as a vented decorative (ANSI Z21.60) product by opening flue damper.

SAFETY PILOT

This heater has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system re- quires no matches, batteries or other sources to light heater.

AIR FOR COMBUSTION

AND VENTILATION

WARNING: This heater shall not be installed in a confined space or unusually tight con- struction unless provisions are provided for adequate combus- tion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.

Todayʼs homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy effi- cient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.

113101-01C

www.desatech.com

5

Image 5
Contents Patent Pending 24 Variable MANUALLY-CONTROLLED ModelsTable of Contents Safety Information Product Identification Local Codes Product FeaturesUnpacking AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Providing Adequate VentilationUnusually Tight Construction Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationMinimum Firebox Size Log Size Side Wall CeilingFront Rear Minimum Noncombustible Material ClearancesLog Set Mantel ClearancesLog Set Floor ClearancesAssembly Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Installation Items Needed Connecting to GAS SupplyNatural Pointing DownTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Installing Back Log Pressure Testing Heater Gas ConnectionsInstallation What to do if YOU Smell GAS Operating HeaterSlightly depress and turn control knob coun Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureVariable Control Operation STOP! Read the safety information, page 20, column Thermostat Control Operation Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceODS/PILOT and Burner Replacement Parts Technical ServiceService Hints Observed Problem Possible Cause Remedy TroubleshootingODS/pilot lights but flame goes See Cleaning and Mainte Statement above Gas leak. See WarningFor Masonry and FACTORY- Built Metal Fireplace Optional Positioning Thermostat Sensing BulbSpecifications Parts Central AccessoriesEquipment Shutoff Valve GA5010 Fireplace HoodIllustrated Parts Breakdown Variable MANUALLY-CONTROLLED Winchester OAK Models Parts ListIllustrated Parts Breakdown THERMOSTATICALLY-CONTROLLED Royal English OAK Models Limited Warranty VENT-FREE GAS Fireplace Warranty InformationKeep this Warranty

CGS2718PA, CGS2718NA, CGS3124PA, CGS3124NA, SGS3124PA, SGS3124NA,CLD3018PTA, CLD3018NTA, CLD3924NTB, CLD3924PTB specifications

The models Desa CGS2718PA, CGS2718NA, CGS3124PA, CGS3124NA, SGS3124PA, SGS3124NA, CLD3018PTA, CLD3018NTA, CLD3924NTB, and CLD3924PTB are part of a versatile range of consumer appliances that combine modern technology with practical design. Each model brings its unique set of features aimed at enhancing user experience while maintaining high performance and efficiency.

Starting with the CGS series, the CGS2718PA and CGS2718NA are known for their compact sizes, making them ideal for smaller spaces without compromising functionality. They offer advanced digital controls, providing users with precise temperature settings and easy operation. Both models feature a sleek design, available in contemporary finishes that complement modern kitchen aesthetics.

The CGS3124PA and CGS3124NA expand on these features, offering greater capacity and additional functionalities such as enhanced cooking modes. These models incorporate the latest multi-cooking technology, allowing users to steam, bake, and roast with ease. Their energy-efficient systems help reduce power consumption while delivering great performance.

In the SGS series, both SGS3124PA and SGS3124NA prioritize efficiency and durability. Their robust construction is designed to withstand the rigors of daily use, while their intuitive controls simplify operation. These models are equipped with smart sensors that monitor cooking conditions and adjust settings automatically, ensuring optimal results every time.

Moving to the CLD series, the CLD3018PTA and CLD3018NTA are designed for versatility, featuring multiple cooking settings that cater to diverse culinary needs. These models excel in user-friendly interfaces, making meal preparation accessible to everyone, from novice cooks to experienced chefs.

The CLD3924NTB and CLD3924PTB stand out with their larger capacity and advanced technology that includes self-cleaning options, programmable timers, and compatibility with smart home systems. This adds another layer of convenience to the cooking process, allowing users to plan meals according to their schedules.

Overall, these models offer a comprehensive approach to modern cooking with an emphasis on efficiency, ease of use, and stylish design. They not only meet the demands of everyday cooking but also enhance the overall experience in the kitchen, making them a valuable addition to any home.