Desa installation manual Warranty Information

Page 40

WARRANTY INFORMATION

KEEP THIS WARRANTY

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY

COMFORT GLOW VENT-FREE NATURAL GAS LOG HEATERS

DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

TM

2701 Industrial Drive

P.O. Box 90004

Bowling Green, KY 42102-9004

www.desatech.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

107123 01

 

 

 

107123-01

 

NOT A UPC

 

 

 

 

 

Rev. F

 

10/02

For..com

Image 40
Contents OWNER’S Operation Installation Manual Unvented VENT-FREE Natural GAS LOG HeatersBiltmore Split OAK, Seasonal OAK, Smoky Mountain OAK Logs What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Unpacking Product Features AIR for Combustion and VentilationLocal Codes Confined and Unconfined Space Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation InstallationCheck GAS Type Minimum Firebox Size Log Front Rear Height Depth WidthIf Not Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Area of Various Standard Round FluesConnecting to GAS Supply Attaching Flexible Gas Hose to Heater Gas RegulatorPressure Testing Gas Supply Piping system Checking GAS ConnectionsPressure Testing Heater Gas Connections Installing LogsDual Burner Smoky Mountain Oak Models Dual Burner Premium Aged Split Oak Models Dual Burner Biltmore Split Oak ModelsInstalling Rear Log Installing Crossover Log Single Burner Seasonal Oak ModelsOperating Heater For Your Safety Read Before LightingLighting Instructions Manual Lighting Procedure Variable Control OperationTo Turn OFF GAS To Appliance Shutting Off HeaterIgnitor Button Cleaning and Maintenance Inspecting BurnersSpecifications LogsModel Models ModelTroubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Top Gas leak. See Warning statement at topOptional Positioning of Thermostat Sensing Bulb For Masonry and Factory-built Metal FireplaceIllustrated Parts Breakdown Parts List Variable Manually-ControlledCGD3018NT CGD3924NT CGD3930NT CGD3018NT CGD3924NT CGD3930NT CCL3018NT Thermostatically-Controlled Biltmore Split Oak ModelCCL3018NT CCL3924NT, CCL3930NTA CCL3924NT CCL3930NTA Variable Manually-Controlled Seasonal Oak Models Variable Manually-Controlled Mountain Oak Models CRL2718N CRL3124NReplacement Parts Service HintsTechnical Service AccessoriesOwners Registration Form Postage Required Parts Central Warranty Information

CGD3018N, CGD3924N, CGD3930N, CRL2718N, CCL3924N, CRL3124N, CCL3018N, CGD3924NT, CGD3018NT, CCL3924NT, CGD3930NT, CCL3018NT, CCL3930NTA specifications

The Desa product line, consisting of models CGD3018N, CGD3924N, CGD3930N, CRL2718N, CCL3924N, CRL3124N, CCL3018N, CGD3924NT, CGD3018NT, CCL3924NT, CGD3930NT, CCL3018NT, and CCL3930NTA, offers a wide range of heating solutions designed to tackle diverse customer needs. These models are distinctive for their durability, efficiency, and user-friendly designs.

Among the standout features of the Desa CGD series, models such as CGD3018N and CGD3924N integrate advanced combustion technologies that maximize fuel efficiency while minimizing emissions. This ensures that users enjoy a cleaner burn and reduced operational costs. The CGD3930N model boasts a higher output, making it suitable for larger spaces, while maintaining a compact design to fit various room layouts.

The CRL series, including CRL2718N and CRL3124N, emphasizes flexibility and ease of installation. These units employ a direct venting system that allows for efficient heat distribution without the need for extensive ductwork. The CCL models, such as CCL3924N and CCL3018N, are designed with aesthetics in mind. They feature sleek styles that blend seamlessly into modern home decors, all while delivering reliable heating performance.

The NT variants, such as CGD3924NT and CCL3924NT, introduce smart technology integration, allowing users to control their heating solutions remotely via smartphone applications. This feature ensures maximum convenience and adaptability to varying user preferences or schedules.

In terms of safety, all models are equipped with built-in features to prevent overheating and ensure stable operation. Additionally, many units incorporate easy-to-use thermostats and adjustable flame settings, providing users with greater control over their indoor climate.

Overall, the Desa models combine innovation with practicality, making them a preferred choice for consumers looking for efficient, stylish, and reliable heating solutions. With a variety of products catering to different preferences and requirements, Desa continues to be a leader in the heating industry, ensuring comfort and satisfaction for all users.