Desa Ventilation AIR, Ventilation Air From Inside Building, Ventilation Air From Outdoors

Page 6

6

AIR FOR COMBUSTION AND VENTILATION

Ventilation Air

AIR FOR COMBUSTION AND VENTILATION

Continued

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and

Ventilation

Grills

Into Adjoining

12"

Ventilation Grills

Into Adjoining Room,

one within 12" of the floor on the wall connecting the two spaces

Room,

Or

Option 2

(see options 1 and 2, Figure 3). You can also remove door into

Option 1

Remove

adjoining room (see option 3, Figure 3). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Door into Adjoining Room, Option 3

12"

Figure 3 - Ventilation Air from Inside Building

Ventilated

Outlet Attic

Air

Outlet

 

Air

To Attic

 

To

Crawl

Space

Inlet

Air

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 4 - Ventilation Air from Outdoors

For..com

107123-01F

Image 6
Contents Biltmore Split OAK, Seasonal OAK, Smoky Mountain OAK Logs OWNER’S Operation Installation ManualUnvented VENT-FREE Natural GAS LOG Heaters What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Product Features AIR for Combustion and Ventilation UnpackingLocal Codes Determining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationInstallation Minimum Firebox Size Log Front Rear Height Depth WidthIf Not Using Mantel Minimum Noncombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Area of Various Standard Round FluesConnecting to GAS Supply Attaching Flexible Gas Hose to Heater Gas RegulatorPressure Testing Gas Supply Piping system Checking GAS ConnectionsInstalling Logs Pressure Testing Heater Gas ConnectionsDual Burner Smoky Mountain Oak Models Dual Burner Premium Aged Split Oak Models Dual Burner Biltmore Split Oak ModelsInstalling Rear Log Installing Crossover Log Single Burner Seasonal Oak ModelsFor Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureVariable Control Operation Shutting Off HeaterIgnitor Button Cleaning and Maintenance Inspecting BurnersModel Models SpecificationsLogs ModelTroubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Top Gas leak. See Warning statement at topOptional Positioning of Thermostat Sensing Bulb For Masonry and Factory-built Metal FireplaceIllustrated Parts Breakdown Parts List Variable Manually-ControlledCGD3018NT CGD3924NT CGD3930NT CGD3018NT CGD3924NT CGD3930NT CCL3018NT Thermostatically-Controlled Biltmore Split Oak ModelCCL3018NT CCL3924NT, CCL3930NTA CCL3924NT CCL3930NTA Variable Manually-Controlled Seasonal Oak Models Variable Manually-Controlled Mountain Oak Models CRL2718N CRL3124NTechnical Service Replacement PartsService Hints AccessoriesOwners Registration Form Postage Required Parts Central Warranty Information

CGD3018N, CGD3924N, CGD3930N, CRL2718N, CCL3924N, CRL3124N, CCL3018N, CGD3924NT, CGD3018NT, CCL3924NT, CGD3930NT, CCL3018NT, CCL3930NTA specifications

The Desa product line, consisting of models CGD3018N, CGD3924N, CGD3930N, CRL2718N, CCL3924N, CRL3124N, CCL3018N, CGD3924NT, CGD3018NT, CCL3924NT, CGD3930NT, CCL3018NT, and CCL3930NTA, offers a wide range of heating solutions designed to tackle diverse customer needs. These models are distinctive for their durability, efficiency, and user-friendly designs.

Among the standout features of the Desa CGD series, models such as CGD3018N and CGD3924N integrate advanced combustion technologies that maximize fuel efficiency while minimizing emissions. This ensures that users enjoy a cleaner burn and reduced operational costs. The CGD3930N model boasts a higher output, making it suitable for larger spaces, while maintaining a compact design to fit various room layouts.

The CRL series, including CRL2718N and CRL3124N, emphasizes flexibility and ease of installation. These units employ a direct venting system that allows for efficient heat distribution without the need for extensive ductwork. The CCL models, such as CCL3924N and CCL3018N, are designed with aesthetics in mind. They feature sleek styles that blend seamlessly into modern home decors, all while delivering reliable heating performance.

The NT variants, such as CGD3924NT and CCL3924NT, introduce smart technology integration, allowing users to control their heating solutions remotely via smartphone applications. This feature ensures maximum convenience and adaptability to varying user preferences or schedules.

In terms of safety, all models are equipped with built-in features to prevent overheating and ensure stable operation. Additionally, many units incorporate easy-to-use thermostats and adjustable flame settings, providing users with greater control over their indoor climate.

Overall, the Desa models combine innovation with practicality, making them a preferred choice for consumers looking for efficient, stylish, and reliable heating solutions. With a variety of products catering to different preferences and requirements, Desa continues to be a leader in the heating industry, ensuring comfort and satisfaction for all users.