Desa installation manual Specifications, Logs, Model Models

Page 21

CLEANING AND MAINTENANCE

Cleaning Burner Injector Holder and Pilot Air Inlet Hole (Cont.)

Logs

Main Burner

SPECIFICATIONS

21

CLEANING AND MAINTENANCE

Continued

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

SPECIFICATIONS

Dual Burner Smoky Mountain Oak and Premium Aged Split Oak Models

 

18" Model

24" Models

30" Models

Btu (Variable)

16,000/30,000

20,000/39,000

20,000/39,000

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 45). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Burner

 

Tube

Injector Holder

Primary Air

Inlet Holes

Figure 44 - Injector Holder On Outlet Burner Tube

Ports/Slots

Burner

Tube

Pilot Assembly

Pilot Air

Inlet Hole

Figure 45 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to Installing Logs, pages 13 through 16, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

Type Gas

 

Natural Gas Only

 

Ignition Piezo

Piezo

Piezo

 

Manifold Pressure

3.5" W.C.

3.5" W.C.

3.5" W.C.

Inlet Gas

 

 

 

Pressure (in. of water)

 

 

 

Maximum

10.5"

10.5"

10.5"

Minimum*

5"

5"

5"

Shipping Weight

36 lbs.

38 lbs.

40 lbs.

* For the purpose of input adjustment

Dual Burner Biltmore Split Oak Models

 

18" Model

24" Models

30" Models

Btu (Variable)

16,000/30,000

20,000/39,000

20,000/39,000

Type Gas

 

Natural Gas Only

 

Ignition Piezo

Piezo

Piezo

 

Manifold Pressure

3.5" W.C.

3.5" W.C.

3.5" W.C.

Inlet Gas

 

 

 

Pressure (in. of water)

 

 

 

Maximum

10.5"

10.5"

10.5"

Minimum*

5"

5"

5"

Shipping Weight

61 lbs.

66 lbs.

70 lbs.

* For the purpose of input adjustment

Single Burner Seasonal Oak Models

 

18" Model

24" Model

Btu (Variable)

16,000/27,000

16,000/31,500

Type Gas

Natural Gas Only

Ignition Piezo

Piezo

 

Manifold Pressure

3.5" W.C.

3.5" W.C.

Inlet Gas

 

 

Pressure (in. of water)

 

 

Maximum

10.5"

10.5"

Minimum*

5"

5"

Shipping Weight

48 lbs.

52 lbs.

* For the purpose of input adjustment

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool, Remove blockage, blocked burner flame holes will create soot.

For morevisit www..com

107123-01F

Image 21
Contents Unvented VENT-FREE Natural GAS LOG Heaters OWNER’S Operation Installation ManualBiltmore Split OAK, Seasonal OAK, Smoky Mountain OAK Logs What to do if YOU Smell GASSafety Information Table of ContentsProduct Identification Product Features AIR for Combustion and Ventilation UnpackingLocal Codes Determining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation InstallationCheck GAS Type Minimum Firebox Size Log Front Rear Height Depth WidthMinimum Noncombustible Material Clearances If Not Using MantelMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Area of Various Standard Round FluesAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping systemInstalling Logs Pressure Testing Heater Gas ConnectionsDual Burner Smoky Mountain Oak Models Dual Burner Biltmore Split Oak Models Dual Burner Premium Aged Split Oak ModelsInstalling Rear Log Single Burner Seasonal Oak Models Installing Crossover LogFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Variable Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterIgnitor Button Inspecting Burners Cleaning and MaintenanceLogs SpecificationsModel Models ModelObserved Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement at top TopFor Masonry and Factory-built Metal Fireplace Optional Positioning of Thermostat Sensing BulbIllustrated Parts Breakdown Variable Manually-Controlled Parts ListCGD3018NT CGD3924NT CGD3930NT CGD3018NT CGD3924NT CGD3930NT Thermostatically-Controlled Biltmore Split Oak Model CCL3018NTCCL3018NT CCL3924NT, CCL3930NTA CCL3924NT CCL3930NTA Variable Manually-Controlled Seasonal Oak Models CRL2718N CRL3124N Variable Manually-Controlled Mountain Oak ModelsService Hints Replacement PartsTechnical Service AccessoriesOwners Registration Form Postage Required Parts Central Warranty Information

CGD3018N, CGD3924N, CGD3930N, CRL2718N, CCL3924N, CRL3124N, CCL3018N, CGD3924NT, CGD3018NT, CCL3924NT, CGD3930NT, CCL3018NT, CCL3930NTA specifications

The Desa product line, consisting of models CGD3018N, CGD3924N, CGD3930N, CRL2718N, CCL3924N, CRL3124N, CCL3018N, CGD3924NT, CGD3018NT, CCL3924NT, CGD3930NT, CCL3018NT, and CCL3930NTA, offers a wide range of heating solutions designed to tackle diverse customer needs. These models are distinctive for their durability, efficiency, and user-friendly designs.

Among the standout features of the Desa CGD series, models such as CGD3018N and CGD3924N integrate advanced combustion technologies that maximize fuel efficiency while minimizing emissions. This ensures that users enjoy a cleaner burn and reduced operational costs. The CGD3930N model boasts a higher output, making it suitable for larger spaces, while maintaining a compact design to fit various room layouts.

The CRL series, including CRL2718N and CRL3124N, emphasizes flexibility and ease of installation. These units employ a direct venting system that allows for efficient heat distribution without the need for extensive ductwork. The CCL models, such as CCL3924N and CCL3018N, are designed with aesthetics in mind. They feature sleek styles that blend seamlessly into modern home decors, all while delivering reliable heating performance.

The NT variants, such as CGD3924NT and CCL3924NT, introduce smart technology integration, allowing users to control their heating solutions remotely via smartphone applications. This feature ensures maximum convenience and adaptability to varying user preferences or schedules.

In terms of safety, all models are equipped with built-in features to prevent overheating and ensure stable operation. Additionally, many units incorporate easy-to-use thermostats and adjustable flame settings, providing users with greater control over their indoor climate.

Overall, the Desa models combine innovation with practicality, making them a preferred choice for consumers looking for efficient, stylish, and reliable heating solutions. With a variety of products catering to different preferences and requirements, Desa continues to be a leader in the heating industry, ensuring comfort and satisfaction for all users.