TROUBLESHOOTING
Continued
WARNING: If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating log set where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
|
|
|
|
|
Log set produces a clicking/tick- | 1. | Metal expanding while heating | 1. | This is common with most log |
ing noise just after burner is lit |
| or contracting while cooling |
| sets. If noise is excessive, con- |
or shut off |
|
|
| tact qualified service person |
|
|
|
|
|
Log set produces unwanted | 1. | Log set burning vapors from | 1. | Open flue to maximum. Stop |
odors |
| paint, hair spray, glues, clean- |
| using odor causing products |
|
| ers, chemicals, new carpet, |
| while log set is running |
|
| etc. (See IMPORTANT state- |
|
|
|
| ment above) |
|
|
| 2. | Gas leak. See Warning | 2. | Locate and correct all leaks |
|
| statement at top of page |
| (see Checking Gas Connec- |
|
|
|
| tions, page 7) |
|
|
|
|
|
Gas odor even when control knob | 1. | Gas leak. See Warning | 1. | Locate and correct all leaks |
is in OFF position |
| statement at top of page |
| (see Checking Gas Connec- |
| 2. | Control valve defective |
| tions, page 7) |
| 2. | Replace control valve | ||
|
|
|
|
|
Gas odor during combustion | 1. | Gas leak. See Warning | 1. | Locate and correct all leaks |
|
| statement at top of page |
| (see Checking Gas Connec- |
|
|
|
| tions, page 7) |
12 | www.desatech.com |