Desa SMS24, SMS18 Checking GAS Connections, Hearth KIT Assembly and Installation

Page 7

INSTALLATION

Continued

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.

WARNING:Neveruseanopen flame to check for a leak. Apply a noncorrosive leak detection fluid toalljoints.Bubblesformingshow a leak. Correct all leaks at once.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect log set and its individual equipment shutoff valve from gas supply piping system.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by either us- ing compressed air or opening main gas valve located on or near gas meter.

4.Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect log set and equipment shutoff valve to gas supply. Check reconnected fit- tings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 5).

2.Pressurize supply piping system by either us- ing compressed air or opening main gas valve located on or near gas meter.

Equipment Shutoff Valve

Gas Meter

3.Check all joints from gas meter to equipment shutoff valve (see Figure 5). Apply noncorro- sive leak detection fluid to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

HEARTH KIT ASSEMBLY AND INSTALLATION

Kit Assembly - Ramp Pan Burner

1.Determine which side the gas line feeds into the fireplace. This log set is factory set up for right side (facing) gas feed. If your gas line is on the right side, go to the Installation and Gas Connection section below. If your gas line is on the left side of the fireplace, proceed with steps 2 through 4 below. Note: Pilot kit can only be installed on the right (facing) side.

2.Remove the nuts securing the gas inlet venturi to the bottom of the burner (see Figure 6).

3.Remove the venturi from the pan taking care not to damage the gasket between the venturi and the pan.

4.Reverse the direction of the venturi and re-attach to the bottom of the pan using factory nuts.

Burner Inlet Fitting

(Factory Installed)

Burner Orifice

(Factory Installed)

Adapter

Fitting

Gas Connector

Tube

Burner Inlet Venturi (Attached to Pan Bottom)

Figure 6 - Connecting Gas to Appliance Installation and Gas Connection

1.Place the ramp burner assembly in the center of the fireplace floor. Make sure the front of pan faces forward.

2.Thread the gas supply fitting to the fireplace gas supply pipe. Use thread sealant.

3.Install the gas connector tube to the gas supply fitting. Carefully shape tube to attach to adapter fitting. Be careful not to cause kinks in tube.

4.Attach opposite end of gas connector tube to

the gas inlet fitting on the end of the venturi.

Figure 5 - Checking Gas Joints

117536-01B

www.desatech.com

7

Image 7
Contents Models SMS18 and SMS24 What to do if YOU Smell GASTable of Contents Safety Information Local Codes Product IdentificationUnpacking Check GAS Type InstallationFlue Opening Specifications Venting Specifications for InstallationMasonry Fireplace Installing Damper ClampConnecting to GAS Supply Installation Items NeededTest Pressures In Excess Of 1/2 Psig 3.5 kPa Hearth KIT Assembly and InstallationKit Assembly Ramp Pan Burner Checking GAS ConnectionsAdding PAN Material Optional GA9200 Series ON/OFF Safety VALVE/PILOT KITTesting Burner for Leaks Installing the Grate and LogsGAS Shutoff Valve Operation For Your Safety Read Before LightingOperating Appliance Lighting InstructionsReplacement Parts Cleaning MaintenanceService Hints Technical ServiceObserved Problem Possible Cause Remedy TroubleshootingGas leak. See Warning Manual Control ON/OFF Safety VALVE/PILOT KIT GA9200 AccessoriesEquipment Shutoff Valve GA5010 Illustrated Parts Breakdown Parts List Keep this Warranty Warranty InformationLimited Lifetime Warranty Vented GAS Logs