Desa SMS24 Operating Appliance, For Your Safety Read Before Lighting, Lighting Instructions

Page 9

INSTALLATION

Continued

Ember

Chunks

Figure 9 - Placement of Top Logs

OPERATING APPLIANCE

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: Keep flue open when operating unit.

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighborʼs phone. Follow the gas supplierʼs instructions.

If you cannot reach your gas supplier, call the fire department.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information on column 1.

2.Turn the gas shutoff valve to OFF.

3.Wait five (5) minutes to clear out any gas. If you then smell gas STOP! Follow the safety information column 1. If you don't smell gas, go on to the next step.

4.Light a match and lay it on top of the pan material about 2" from the end of the sup- ply side of the pan

5.Slowly turn the gas shutoff valve ON until the burner ignites. If the burner doesnʼt ignite within 10 seconds with the match burning, turn the shutoff valve OFF and repeat steps 1 through 4 again.

 

GAS SHUTOFF

 

VALVE OPERATION

 

Flame Adjustment

 

Adjust the flame ON/OFF by turning the gas

shutoff valve counterclockwise

to open

or clockwise

to close, as necessary.

Shutting Off Appliance

 

Turn gas shutoff valve clockwise

to the

OFF position.

 

 

CURING

 

 

LOGS

 

During the 2-3 hour appliance break-in period,

you may detect an odor from the appliance

as the various paints and compounds used in

the manufacturing of this log set cure. This is

a normal and temporary situation that is not

cause for alarm. However, you may want to

provide extra ventilation to the room during

this time.

 

 

To ensure proper curing of the logs:

 

Ignite a 2" flame and maintain it for 1 hour.

Burn the logs in consecutive 1 hour periods raising the flame an additional 2" to full flame height for a total of three hours.

117536-01B

www.desatech.com

9

Image 9
Contents Models SMS18 and SMS24 What to do if YOU Smell GASTable of Contents Safety Information Product Identification Local CodesUnpacking Flue Opening Specifications InstallationVenting Specifications for Installation Check GAS TypeConnecting to GAS Supply Installing Damper ClampInstallation Items Needed Masonry FireplaceKit Assembly Ramp Pan Burner Hearth KIT Assembly and InstallationChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaTesting Burner for Leaks Optional GA9200 Series ON/OFF Safety VALVE/PILOT KITInstalling the Grate and Logs Adding PAN MaterialOperating Appliance For Your Safety Read Before LightingLighting Instructions GAS Shutoff Valve OperationService Hints Cleaning MaintenanceTechnical Service Replacement PartsObserved Problem Possible Cause Remedy TroubleshootingGas leak. See Warning Accessories Manual Control ON/OFF Safety VALVE/PILOT KIT GA9200Equipment Shutoff Valve GA5010 Illustrated Parts Breakdown Parts List Warranty Information Keep this WarrantyLimited Lifetime Warranty Vented GAS Logs