Bosch Appliances BC2600RA installation manual Maintenance, Handling after trial operation

Page 16

Installation Instructions

11. Maintenance

Periodically check the following to ensure proper

operation of the water heater.

The venting system must be examined periodically by a qualified service technician to check for any leaks or corrosion.

The burner flame must be checked periodically for a proper blue colour and consistency.

If the flame does not appear normal, the burner may need to be cleaned.

If the burner needs to be cleaned, it must be performed by a qualified service technician.

Do not obstruct the flow of combustion and ventilation air.

See Owner's Guide for further maintenance.

Warning: There is a scald potential if the output temperature is set too high.

Should overheating occur, or the gas supply fail to shut off, turn off the manual gas control valve to the appliance. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Periodically check and clean the filter inside the cold water inlet of the unit.

The installer should test operate the unit, explain to 12. Trial Operation the customer how to use the unit, and give the owner

this manual before leaving the installation.

Preparation ........... (1) Open a hot water fixture to confirm that water is available, and then close the fixture.

(2)Open the gas supply valve.

(3)Turn on the power supply. Using the remote controller, turn on the Power On/Off button (the Operation lamp will turn on).

(1)Open a hot water fixture and confirm that the Burner On lamp comes on, and that hot water is being produced. (If necessary, repeat until the air in the gas piping is bled out).

*White smoke may be noticed from the exhaust vent during cold weather. However, this is not a malfunction of the unit.

*If an “11” error code appears on the remote controller, turn the unit off and then back on again, and then open a hot water fixture again.

(2)Change the temperature setting on the remote controller and check that the water temperature changes.

If the water heater does not operate normally, refer to “Troubleshooting” in the Owner's Guide. * After the trial operation, clean the filter in the cold water inlet.

CAUTION

Handling after trial operation

If the unit will not be used immediately, close off all gas and water shutoff valves, drain all of the water out of the unit and the plumbing system to prevent the unit and system from freezing, and bleed the gas out of the gas line.

Freezing is not covered by the warranty.

16

Image 16
Contents Installation Manual Installation Manual Included Accessories Before Installation Use Extreme Caution if Using With a Solar Pre-HeaterCheck the Gas Check Water Supply QualityChoosing Installation Site IndoorInstallation Clearances Before installing, check for the followingClearances for Flue Terminal front of heater Installation Securing to the wallGas Piping Gas PressureGas Meter Measuring Gas Pressure Gas ConnectionWater Piping Drain processing Supply water pipingHot water piping Condensate Piping Electrical Wiring EarthYPRM67XB Connecting Remote Controller Cord to Unit Maintenance Handling after trial operationLighting Instructions Dimensions 338