Bosch Appliances BC2600RA Installation Clearances, Before installing, check for the following

Page 6

Installation Instructions

CAUTION

Install the water heater in a location where it is free from obstacles and stagnant air.

Consult with the customer concerning the location of installation.

Do not install the water heater near staircases or emergency exits.

Do not install the water heater where the exhaust will blow on outer walls or material not resistant to heat. Also consider the surrounding trees and animals.

The heat and moisture from the water heater may cause discoloration of walls and resinous materials, or corrosion of aluminium materials.

Do not locate the vent termination directed towards a window or any

Prohibited

 

other structure which has glass or wired glass facing the termination.

 

Install in a location where the exhaust gas flow will not be affected by

 

 

fans or range hoods.

 

Take care that noise and exhaust gas will not affect neighbours.

Avoid installation where the unit will be exposed to excessive winds.

Before installing, make sure that the vent termination will have the proper clearances according to AS5601, or your local authority.

On combustible surfaces e.g. weatherboards etc. it is not required to install a fire proof back board.

5.Installation Clearances

WARNING

Before installing, check for the following:

The location of the flue terminal must comply with the clearances shown on this page. If you are unsure about clearances not indicated here, in general refer to AS5601, or your local authority. In Western Australia refer to the WA Office of Energy rules and regulations.

Flue outlet must be free from any combustible material.

6

Image 6
Contents Installation Manual Installation Manual Included Accessories Check the Gas Before InstallationUse Extreme Caution if Using With a Solar Pre-Heater Check Water Supply QualityChoosing Installation Site IndoorInstallation Clearances Before installing, check for the followingClearances for Flue Terminal front of heater Installation Securing to the wallGas Meter Gas PipingGas Pressure Measuring Gas Pressure Gas ConnectionWater Piping Supply water piping Drain processingHot water piping Condensate Piping Electrical Wiring EarthYPRM67XB Connecting Remote Controller Cord to Unit Maintenance Handling after trial operationLighting Instructions Dimensions 338