Installation Instructions
3. Before Installation
![]()
WARNING
Check the Gas
•Check that the data plate (located inside of front cover) or a temporary label (located on the front cover)
indicates the correct type of gas. | For NG Gas |
| |||
• Check that the gas supply line is sized for |
|
|
|
| |
178 MJ/hr for this unit. |
|
|
|
| |
• DO NOT OPERATE WITH ANY OTHER GAS TYPE. |
| MODEL BC2600RA |
| ||
|
|
| GAS TYPE | : NG | |
Check the Power |
|
| GAS CONSUMPTION | : 178MJ/hr | |
|
| HEAT OUTPUT | : 45.7kW | ||
• The power supply required is 240/230VAC, at 50Hz. |
| ELECTRICAL RATING | : AC240/230V 50Hz | ||
| RATED POWER | : 56.0W | |||
Using the incorrect voltage may result in fire or |
| HOT WATER SUPPLY CAPACITY | : 26L/min RAISED 25°C | ||
|
| TEST POINT | : MAX : 0.73kPa | ||
electric shock. |
|
| |||
|
|
| : MIN : 0.18kPa | ||
|
|
|
| ||
|
|
| GAS SUPPLY PRESSURE | MAX 3 0kP | |
Warning labels
• Located on the right side of the casing
Use Extreme Caution if Using With a Solar Pre-Heater
•A solar transfer valve must be installed with all solar applications when using Bosch Eco 26+.
•Solar systems installed without a solar transfer valve will void all Bosch warranty.
![]()
CAUTION
Do Not Use Equipment for Purposes Other Than Those Specified
•Do not use for other than increasing the temperature of the water supply, as unexpected accidents may occur as a result.
Check Water Supply Quality
•If the water supply is hard, acidic or otherwise impure, treat the water with approved methods in order to ensure full warranty coverage.
4