Appliance details
The maximum flue gas exhaust temperature on the 250 SX is 437°F (225°C)
Venting | Exhaust | * Exhaust | * Exhaust | Combustion | Combustion | Vent pipe | Vent pipe |
Options | vent | vent | vent | air pipe | air pipe | clearances | clearances |
| diameter | maximum | minimum | diameter | maximum | within an | within an |
| and | length | length | and material | length | unenclosed | enclosed |
| material |
|
|
|
| space | space |
|
|
|
|
|
|
|
|
Room | 3 inch | 26 feet (8 | 3 feet | 3 inch PVC, | 26 feet (8 | ** See vent | ** See vent |
sealed | stainless | m) with one |
| aluminum or | m) with one | manufacturer's | manufacturer's |
(twin pipe) | steel | elbow. Less |
| galvanized | elbow. Less | specifications | specifications |
| 2½ feet for |
| pipe | 2½ feet for |
|
| |
| sealed vent | each |
|
| each |
|
|
| pipe | additional |
|
| additional |
|
|
|
| 90° elbow |
|
| 90° elbow |
|
|
Open | 3 inch | 26 feet (8 | 3 feet | See | See | ** See vent | ** See vent |
combustion | stainless | m) with one |
| chapter 2.8 | chapter 2.8 | manufacturer's | manufacturer's |
(single | steel | elbow. Less |
|
|
| specifications | specifications |
pipe) | 2½ feet for |
|
|
|
|
| |
| sealed vent | each |
|
|
|
|
|
| pipe | additional |
|
|
|
|
|
|
| 90° elbow |
|
|
|
|
|
|
|
|
|
|
|
|
|
Exhaust vent is always fan assisted. Installation of exhaust vent and combustion air piping may be run vertically or horizontally and in separate directions if required.
*A maximum of three 90 degree elbows are permitted in the total vent length. The total vent length must be reduced by 1 ¼ feet for every 45° elbow used in the vent system.
** Stainless steel
Table 2
10 | 6 720 607 057 |