Bosch Appliances 250SX LP, 250SX NG Appliance details, Features, SX Specifications Technical data

Page 4

Appliance details

2Appliance details

2.1Features

Parts

Touch Pad interface control

High power pre-mix compact burner with low Nox emissions

Modulating Gas Valve with constant gas:air ratio control

Modulating water valve for improved comfort and temperature control.

Safety

Flame sensor (ionization) rod

Overheat sensor

Temperature limiter

Fan speed monitoring.

High Quality Materials for Long Working Life

Copper heat exchanger

Ceramic Burner output

Automatic overheating protection shut-off sensor

Compact space saver: mounts on a wall with a supplied bracket.

Easily removable one-piece cover.

Features

LCD Display

On/Off and Temperature control switches

Reset button

Program Key (Selectable temperature default)

Failure codes for easy diagnostic and repair. Accessories

Optional wireless remote control accessory to operate with the appliance

Vent termination kit.

BOSCH is constantly improving its

iproducts, therefore specifications are subject to change without prior notice.

2.2250 SX Specifications (Technical data)

Approved in US/Canada

Capacity

Maximum flow rate: 6.35 GPM (24 l/min) at a 45°F (25°C) rise.

Maximum output

142,968 Btu/h (41.8 kW)

Maximum input

175,000 Btu/h (51.2 kW)

Efficiency in %

Recovery efficiency 86.5%

Min. Output

31,131 Btu/h (9.1 kW)

Temperature Control

Selection range: 100°F (38°C) - 140°F (60°C)

Default temperature: 122°F (50°C)

Stability: +/- 2°F (+/- 1°C)

Gas Requirement

Gas connection (inches) - ¾”

Inlet gas pressure under operation (with a high hot water flow rate)*

Propane: 11” - 14” water column

Natural Gas: 5” - 14” water column

Gas pressure measuring point inside the appliance at the gas valve inlet.

*Testing with a manometer, operate other gas equipment on the same gas supply. Gas pressures lower than 5" W.C. for Natural Gas or 11" W.C. for LPG will result in insufficient degree rise to the hot water being used. See Measuring Gas Pressure, chapter 2.12.

Fig. 3 Gas pressure measuring point

Venting

See chapter 2.9 for Venting on page 9.

Water

Hot water connection (inches) - ¾”

Cold water connection (inches) - ¾”

Water valve material: Polymer (PPS) (Polypropylene Sulfid)

Minimum water flow: 0.8 gallon/minute (3 l/m)

4

6 720 607 057

Image 4
Contents SX NG SX LP What to do if you smell gasFor your safety IndexIndex FeaturingFCC 250 SX Specifications Technical data FeaturesAppliance details Dimensions Safety devicesCombustion Gas typesDimensions and Minimum installation clearances DimensionsGeneral rules to follow for safe operation Proper location for installing your heaterVenting Clearances Mounting installationCombustion air requirements Venting Room Minimum exhaust vent size and length Venting optionsAppliance details Room sealed installation Twin Pipe System Open combustion installation Single Pipe SystemDescription Minimum distance 720 607 Shown GAS Line SizingFor Natural GAS For LP GASGas line sizing Be Included in the Pipe SizingWater connections Plumbing Connections and Pressure Relief ValveFor your safety read before operating your water heater Electrical connectionsOperating instructions What to do if YOU Smell GASTo Turn OFF GAS to Appliance Power Temperature selectionOperation instructions Operation instructionsOperation instructions Setting the water temperature Flow/temperature chartsUse of remote control accessory Reset buttonOperation Program buttonMaintenance and service TroubleshootingTemperature balance valves TroubleshootingUnbalanced pressure in water lines Troubleshooting Display Cause Solution ChapterElectrical diagram Electrical diagramSX Functional scheme SX Functional schemeInterior components diagram and parts list Interior components diagram and parts listInterior components Components diagram Components DiagramParts list Description ReferenceSpecial adjustment for measuring and adjusting CO2 levels Adjusting the unitAdjusting Leave Program modeProtecting the environment Protecting the environmentPacking ComponentsTwelve Year Limited Warranty Controlled Energy Corp