Bosch Appliances 250SX LP, 250SX NG manual Maintenance and service, Troubleshooting

Page 24

Maintenance and service

4Maintenance and service

Warning: Always turn off the electrical power supply, turn off the manual gas valve and turn off the manual water control valves whenever servicing.

The unit should be checked once a year by a gas technician. If repairs are needed, the repairs should be done by a gas technician

To remove front cover

BRemove plastic decals on front panel (Page 5, Fig. 4).

BLoosen the two Philips head screws located behind decals.

BLift front cover panel upward and remove.

Systems and parts that should be checked at least once a year

Reference diagrams on pages 29 and 30.

Venting system

Burners -see page 29 for observation window

Manual operation of the pressure relief valve to insure correct operation

Periodic cleaning of the water filter screen, see Fig. 24, chapter 2.13.

Flushing the heat exchanger with a descaling solution if mineral build up is evident. Scale build up will shorten the life of the water heater, descale heat exchanger thoroughly and repeat annually depending on mineral content of ground water.

5Troubleshooting

Introduction

The 250 SX burner is activated by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient water flow volume to activate the burners at its minimum flow requirement; Dirt in the water flow valve causing it to malfunction; Sediment build-up in faucet aerators, or shower heads; Uneven pressures between cold and hot (with single lever mix valves); and Plumbing crossovers. These water flow related problems can cause the heater to deliver less than its full output, or to fail to ignite or to shut down completely.

Problems stated below in upper case and in bold face should be investigated when there is a problem with the performance of the water heater but there is NO error code on the heater's LCD display or wireless remote control.

Any failures that result in a displayed error code are referenced on page 26. A Functional Scheme of the 250 SX is detailed on page 28. If there is a problem with the installation, venting or operation of the unit, the

heater will communicate the source by these error codes.

BURNERS DO NOT IGNITE WHEN HOT WATER IS TURNED ON

Cold incoming water connection made to wrong side of heater

Make sure cold water inlet connection is plumbed to the right side of heater when facing unit

Water flow rate at hot water tap is too low

A minimum of 0.8 gallon/minute (3 l/m) is required to activate the heater

Cold water inlet filter screen is dirty

Remove water inlet filter screen and clean. The screen is located at the inlet connection to the water heater, disconnecting the main cold supply line at the heater is required. Check and clean faucet aerator screens too.

Crossover in plumbing

The heater activates when there is sufficient water flow through its water valve, a minimum of 0.8 gallon/ minute (3 l/m) is required. If there is a crossover in the plumbing, the necessary hot water flow rate through the unit may not be reached, even though the flow at the hot water tap is sufficient. A plumbing crossover can be caused by a failed washer at a single lever faucet, incorrect plumbing or a faulty mixing valve in the piping. The crossover will create a back pressure on the water heater and prevent an adequate flow of water through it. To confirm there is no crossover in the plumbing, shut off the cold water supply feed to the water heater. Individually open each of the hot water taps. There should be no water flowing under a constant pressure. If there is a constant flow of water then the plumbing crossover must be corrected before the heater can operate properly.

WATER IS TOO HOT

Temperature selection too high

Lower temperature adjustment on heater or wireless remote control accessory, see chapter 3.2.

WATER IS NOT HOT ENOUGH

Temperature selection too low

Increase temperature adjustment on heater or wireless remote control accessory, see chapter 3.2

Btu input is too low due to inadequate gas line sizing

See specifications in chapter 2.10 - 2.12. The 250 SX requires adequate gas pressure to reach desired temperatures, to compensate for inadequate gas supply or lack of gas pressure the 250 SX will effectively reach the selected output temperature by reducing the hot water flow rate. Its motorized water valve makes this adjustment

Cold water is mixing with the hot water outlet (crossover)

24

6 720 607 057

Image 24
Contents SX NG SX LP What to do if you smell gasFor your safety IndexIndex FeaturingFCC Features 250 SX Specifications Technical dataAppliance details Dimensions Safety devicesCombustion Gas typesDimensions and Minimum installation clearances DimensionsProper location for installing your heater General rules to follow for safe operationVenting Mounting installation ClearancesCombustion air requirements Venting Room Minimum exhaust vent size and length Venting optionsAppliance details Room sealed installation Twin Pipe System Open combustion installation Single Pipe SystemDescription Minimum distance 720 607 Shown GAS Line SizingFor Natural GAS For LP GASGas line sizing Be Included in the Pipe SizingWater connections Plumbing Connections and Pressure Relief ValveFor your safety read before operating your water heater Electrical connectionsOperating instructions What to do if YOU Smell GASTo Turn OFF GAS to Appliance Power Temperature selectionOperation instructions Operation instructionsOperation instructions Setting the water temperature Flow/temperature chartsUse of remote control accessory Reset buttonOperation Program buttonMaintenance and service TroubleshootingTroubleshooting Temperature balance valvesUnbalanced pressure in water lines Troubleshooting Display Cause Solution ChapterElectrical diagram Electrical diagramSX Functional scheme SX Functional schemeInterior components diagram and parts list Interior components diagram and parts listInterior components Components diagram Components DiagramParts list Description ReferenceSpecial adjustment for measuring and adjusting CO2 levels Adjusting the unitAdjusting Leave Program modeProtecting the environment Protecting the environmentPacking ComponentsTwelve Year Limited Warranty Controlled Energy Corp